Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correction
Gespeichert in:
Verfasser / Beitragende:
[Ulrike Attenberger, Ciprian Catana, Hersh Chandarana, Onofrio Catalano, Kent Friedman, Stefan Schonberg, James Thrall, Marco Salvatore, Bruce Rosen, Alexander Guimaraes]
Ort, Verlag, Jahr:
2015
Enthalten in:
Abdominal Imaging, 40/6(2015-08-01), 1374-1386
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 60549228X | ||
| 003 | CHVBK | ||
| 005 | 20210128100514.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20150801xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s00261-015-0455-3 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s00261-015-0455-3 | ||
| 245 | 0 | 0 | |a Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correction |h [Elektronische Daten] |c [Ulrike Attenberger, Ciprian Catana, Hersh Chandarana, Onofrio Catalano, Kent Friedman, Stefan Schonberg, James Thrall, Marco Salvatore, Bruce Rosen, Alexander Guimaraes] |
| 520 | 3 | |a Simultaneous data collection for positron emission tomography and magnetic resonance imaging (PET/MR) is now a reality. While the full benefits of concurrently acquiring PET and MR data and the potential added clinical value are still being evaluated, initial studies have identified several important potential pitfalls in the interpretation of fluorodeoxyglucose (FDG) PET/MRI in oncologic whole-body imaging, the majority of which being related to the errors in the attenuation maps created from the MR data. The purpose of this article was to present such pitfalls and artifacts using case examples, describe their etiology, and discuss strategies to overcome them. Using a case-based approach, we will illustrate artifacts related to (1) Inaccurate bone tissue segmentation; (2) Inaccurate air cavities segmentation; (3) Motion-induced misregistration; (4) RF coils in the PET field of view; (5) B0 field inhomogeneity; (6) B1 field inhomogeneity; (7) Metallic implants; (8) MR contrast agents. | |
| 540 | |a Springer Science+Business Media New York, 2015 | ||
| 690 | 7 | |a PET/MRI |2 nationallicence | |
| 690 | 7 | |a Attenuation correction |2 nationallicence | |
| 690 | 7 | |a Pitfalls |2 nationallicence | |
| 700 | 1 | |a Attenberger |D Ulrike |u Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany |4 aut | |
| 700 | 1 | |a Catana |D Ciprian |u Department of Radiology, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 02129, Charlestown, MA, USA |4 aut | |
| 700 | 1 | |a Chandarana |D Hersh |u Department of Radiology, New York University Medical Center, New York, NY, USA |4 aut | |
| 700 | 1 | |a Catalano |D Onofrio |u Department of Radiology, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 02129, Charlestown, MA, USA |4 aut | |
| 700 | 1 | |a Friedman |D Kent |u Department of Radiology, New York University Medical Center, New York, NY, USA |4 aut | |
| 700 | 1 | |a Schonberg |D Stefan |u Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany |4 aut | |
| 700 | 1 | |a Thrall |D James |u Department of Radiology, Massachusetts General Hospital, 02114, Boston, MA, USA |4 aut | |
| 700 | 1 | |a Salvatore |D Marco |u SDN IRCCS, University of Naples, Naples, Italy |4 aut | |
| 700 | 1 | |a Rosen |D Bruce |u Department of Radiology, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 02129, Charlestown, MA, USA |4 aut | |
| 700 | 1 | |a Guimaraes |D Alexander |u Department of Radiology, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 02129, Charlestown, MA, USA |4 aut | |
| 773 | 0 | |t Abdominal Imaging |d Springer US; http://www.springer-ny.com |g 40/6(2015-08-01), 1374-1386 |x 0942-8925 |q 40:6<1374 |1 2015 |2 40 |o 261 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00261-015-0455-3 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a review-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s00261-015-0455-3 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Attenberger |D Ulrike |u Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Catana |D Ciprian |u Department of Radiology, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 02129, Charlestown, MA, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Chandarana |D Hersh |u Department of Radiology, New York University Medical Center, New York, NY, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Catalano |D Onofrio |u Department of Radiology, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 02129, Charlestown, MA, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Friedman |D Kent |u Department of Radiology, New York University Medical Center, New York, NY, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Schonberg |D Stefan |u Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Thrall |D James |u Department of Radiology, Massachusetts General Hospital, 02114, Boston, MA, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Salvatore |D Marco |u SDN IRCCS, University of Naples, Naples, Italy |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Rosen |D Bruce |u Department of Radiology, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 02129, Charlestown, MA, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Guimaraes |D Alexander |u Department of Radiology, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, 02129, Charlestown, MA, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Abdominal Imaging |d Springer US; http://www.springer-ny.com |g 40/6(2015-08-01), 1374-1386 |x 0942-8925 |q 40:6<1374 |1 2015 |2 40 |o 261 | ||