MR-PET co-registration in upper abdominal imaging: quantitative comparison of two different T1-weighted gradient echo sequences: initial observations

Verfasser / Beitragende:
[Miguel Ramalho, Mamdoh AlObaidy, Lauren Burke, Brian Dale, Kiran Busireddy, Terence Wong, Abdulaziz AlSugair, Richard Semelka]
Ort, Verlag, Jahr:
2015
Enthalten in:
Abdominal Imaging, 40/6(2015-08-01), 1426-1431
Format:
Artikel (online)
ID: 605492948
LEADER caa a22 4500
001 605492948
003 CHVBK
005 20210128100518.0
007 cr unu---uuuuu
008 210128e20150801xx s 000 0 eng
024 7 0 |a 10.1007/s00261-015-0460-6  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s00261-015-0460-6 
245 0 0 |a MR-PET co-registration in upper abdominal imaging: quantitative comparison of two different T1-weighted gradient echo sequences: initial observations  |h [Elektronische Daten]  |c [Miguel Ramalho, Mamdoh AlObaidy, Lauren Burke, Brian Dale, Kiran Busireddy, Terence Wong, Abdulaziz AlSugair, Richard Semelka] 
520 3 |a Purpose: The purpose of this study is to quantitatively compare the accuracy of spatial registration of Cartesian breath-hold 3D-GRE and non-respiratory-triggered free-breathing radial 3D-GRE images with PET data acquisition on whole-body hybrid MR-PET system. Materials and methods: Eight patients (six men and two women; mean age, 56.6±5.5 years) with nine ablated hepatocellular carcinomas constituted our study population. Spatial coordinates (x, y, z) of the estimated isocenters of the ablated areas were independently determined by two radiologists. Both T1-weighted sequences were performed in the axial plane. Distance between the isocenter of the lesion on PET images and on both T1-weighted images was measured, and misregistration was calculated. Statistical analysis was performed using Student t test. Results: Misalignment values of the hepatic ablation zones between PET and MR images were calculated at 4.94±1.35 mm (reader 1) and 4.89±2.21 mm (reader 2) for Cartesian 3D-GRE sequence, and 2.48±0.65 mm (reader 1) and 2.72±0.44 mm (reader 2) for the radial 3D-GRE sequence, with p values of 0.0011 and 0.0133, respectively. Conclusion: Radial 3D-GRE offers improved registration accuracy with PET, supporting the use of this T1-weighted sequence in upper abdominal MR-PET studies. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a MR-PET  |2 nationallicence 
690 7 |a Registration  |2 nationallicence 
690 7 |a Alignment  |2 nationallicence 
690 7 |a Radial  |2 nationallicence 
690 7 |a Cartesian  |2 nationallicence 
690 7 |a 3D-GRE  |2 nationallicence 
700 1 |a Ramalho  |D Miguel  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
700 1 |a AlObaidy  |D Mamdoh  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
700 1 |a Burke  |D Lauren  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
700 1 |a Dale  |D Brian  |u Siemens Medical Solution, Cary, NC, USA  |4 aut 
700 1 |a Busireddy  |D Kiran  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
700 1 |a Wong  |D Terence  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
700 1 |a AlSugair  |D Abdulaziz  |u Department of Radiology, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia  |4 aut 
700 1 |a Semelka  |D Richard  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
773 0 |t Abdominal Imaging  |d Springer US; http://www.springer-ny.com  |g 40/6(2015-08-01), 1426-1431  |x 0942-8925  |q 40:6<1426  |1 2015  |2 40  |o 261 
856 4 0 |u https://doi.org/10.1007/s00261-015-0460-6  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s00261-015-0460-6  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ramalho  |D Miguel  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a AlObaidy  |D Mamdoh  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Burke  |D Lauren  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Dale  |D Brian  |u Siemens Medical Solution, Cary, NC, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Busireddy  |D Kiran  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Wong  |D Terence  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a AlSugair  |D Abdulaziz  |u Department of Radiology, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Semelka  |D Richard  |u Department of Radiology, University Of North Carolina at Chapel Hill, Old Clinic Bldg., CB 7510 - 2001, 27599-7510, Chapel Hill, NC, USA  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Abdominal Imaging  |d Springer US; http://www.springer-ny.com  |g 40/6(2015-08-01), 1426-1431  |x 0942-8925  |q 40:6<1426  |1 2015  |2 40  |o 261