Comparison of calculated and acquired high b value diffusion-weighted imaging in prostate cancer

Verfasser / Beitragende:
[Kinzya Grant, Harsh Agarwal, Joanna Shih, Marcelino Bernardo, Yuxi Pang, Dagane Daar, Maria Merino, Bradford Wood, Peter Pinto, Peter Choyke, Baris Turkbey]
Ort, Verlag, Jahr:
2015
Enthalten in:
Abdominal Imaging, 40/3(2015-03-01), 578-586
Format:
Artikel (online)
ID: 605494118
LEADER caa a22 4500
001 605494118
003 CHVBK
005 20210128100524.0
007 cr unu---uuuuu
008 210128e20150301xx s 000 0 eng
024 7 0 |a 10.1007/s00261-014-0246-2  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s00261-014-0246-2 
245 0 0 |a Comparison of calculated and acquired high b value diffusion-weighted imaging in prostate cancer  |h [Elektronische Daten]  |c [Kinzya Grant, Harsh Agarwal, Joanna Shih, Marcelino Bernardo, Yuxi Pang, Dagane Daar, Maria Merino, Bradford Wood, Peter Pinto, Peter Choyke, Baris Turkbey] 
520 3 |a Purpose: To determine whether the performance of calculated high b value diffusion-weighted images (DWI) derived from regular lower b value DWI using exponential diffusion decay models (intravoxel incoherent motion=IVIM and diffusional kurtosis=DK) is comparable to acquired high b value DWI in prostate cancer detection. Materials and Methods: One hundred six patients underwent diagnostic multiparametric prostate MRI at 3T using an endorectal coil. Five b value (b=0, 188, 375, 563, 750s/mm2) DWI and high b value (b=0, 1000 and 2000s/mm2) DWI were acquired. Calculated high b value (b=1000s/mm2 and b=2000s/mm2) DWI were derived from the DWI dataset using DK and IVIM models. Calculated and acquired high b value DWI images were compared for lesion visibility and image quality by two experienced radiologists (1 and 6years of experience). GEE with Wald test was used to compare the image quality among the four calculated high b value DWI by comparing the proportion of lesions in each model which were comparable to the acquired images. This comparison was done for all lesions and by lesion location (PZ or CG; low apical/anterior or apical/mid/base) Results: More lesions were visible on acquired b=2000s/mm2 compared to b=1000s/mm2 DWI. Calculated high b value DWI using the IVIM model had approximately the same number of lesions as acquired high b value DWI, whereas the DK model had fewer lesions than acquired images. The image quality of calculated high b value DWI was comparable to that of acquired images, and the highest quality images were obtained with b1000IVIM. The image quality of calculated b1000IVIM was the same as that of acquired DWI in apical/mid/base (98%) locations and comparable in low apical and anterior (95.4%) locations. The image quality of calculated b2000IVIM was inferior in both apical/mid/base (86.2%) locations and comparable in low apical and anterior (83.9%) locations. Conclusion: Calculated high b value DWI obtained using IVIM model has same lesion visibility as that of acquired DWI. The image quality of calculated high b value DWI relative to corresponding acquired DWI decreases with increase in b value. 
540 |a Springer Science+Business Media New York, 2014 
690 7 |a Prostate cancer  |2 nationallicence 
690 7 |a MRI  |2 nationallicence 
690 7 |a Diffusion-weighted imaging  |2 nationallicence 
690 7 |a High b value  |2 nationallicence 
700 1 |a Grant  |D Kinzya  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
700 1 |a Agarwal  |D Harsh  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
700 1 |a Shih  |D Joanna  |u Biometric Research Branch, Division of Cancer Treatment and Diagnosis, NCI, NIH, Bethesda, MD, USA  |4 aut 
700 1 |a Bernardo  |D Marcelino  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
700 1 |a Pang  |D Yuxi  |u Philips Healthcare, Cleveland, OH, USA  |4 aut 
700 1 |a Daar  |D Dagane  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
700 1 |a Merino  |D Maria  |u Laboratory of Pathology, NCI, NIH, Bethesda, MD, USA  |4 aut 
700 1 |a Wood  |D Bradford  |u Clinical Center, Center for Interventional Oncology, NCI and Radiology and Imaging Sciences, NIH, Bethesda, MD, USA  |4 aut 
700 1 |a Pinto  |D Peter  |u Urologic Oncology Branch, NCI, NIH, Bethesda, MD, USA  |4 aut 
700 1 |a Choyke  |D Peter  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
700 1 |a Turkbey  |D Baris  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
773 0 |t Abdominal Imaging  |d Springer US; http://www.springer-ny.com  |g 40/3(2015-03-01), 578-586  |x 0942-8925  |q 40:3<578  |1 2015  |2 40  |o 261 
856 4 0 |u https://doi.org/10.1007/s00261-014-0246-2  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s00261-014-0246-2  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Grant  |D Kinzya  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Agarwal  |D Harsh  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Shih  |D Joanna  |u Biometric Research Branch, Division of Cancer Treatment and Diagnosis, NCI, NIH, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Bernardo  |D Marcelino  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Pang  |D Yuxi  |u Philips Healthcare, Cleveland, OH, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Daar  |D Dagane  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Merino  |D Maria  |u Laboratory of Pathology, NCI, NIH, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Wood  |D Bradford  |u Clinical Center, Center for Interventional Oncology, NCI and Radiology and Imaging Sciences, NIH, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Pinto  |D Peter  |u Urologic Oncology Branch, NCI, NIH, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Choyke  |D Peter  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Turkbey  |D Baris  |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Abdominal Imaging  |d Springer US; http://www.springer-ny.com  |g 40/3(2015-03-01), 578-586  |x 0942-8925  |q 40:3<578  |1 2015  |2 40  |o 261