Comparison of calculated and acquired high b value diffusion-weighted imaging in prostate cancer
Gespeichert in:
Verfasser / Beitragende:
[Kinzya Grant, Harsh Agarwal, Joanna Shih, Marcelino Bernardo, Yuxi Pang, Dagane Daar, Maria Merino, Bradford Wood, Peter Pinto, Peter Choyke, Baris Turkbey]
Ort, Verlag, Jahr:
2015
Enthalten in:
Abdominal Imaging, 40/3(2015-03-01), 578-586
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605494118 | ||
| 003 | CHVBK | ||
| 005 | 20210128100524.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20150301xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s00261-014-0246-2 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s00261-014-0246-2 | ||
| 245 | 0 | 0 | |a Comparison of calculated and acquired high b value diffusion-weighted imaging in prostate cancer |h [Elektronische Daten] |c [Kinzya Grant, Harsh Agarwal, Joanna Shih, Marcelino Bernardo, Yuxi Pang, Dagane Daar, Maria Merino, Bradford Wood, Peter Pinto, Peter Choyke, Baris Turkbey] |
| 520 | 3 | |a Purpose: To determine whether the performance of calculated high b value diffusion-weighted images (DWI) derived from regular lower b value DWI using exponential diffusion decay models (intravoxel incoherent motion=IVIM and diffusional kurtosis=DK) is comparable to acquired high b value DWI in prostate cancer detection. Materials and Methods: One hundred six patients underwent diagnostic multiparametric prostate MRI at 3T using an endorectal coil. Five b value (b=0, 188, 375, 563, 750s/mm2) DWI and high b value (b=0, 1000 and 2000s/mm2) DWI were acquired. Calculated high b value (b=1000s/mm2 and b=2000s/mm2) DWI were derived from the DWI dataset using DK and IVIM models. Calculated and acquired high b value DWI images were compared for lesion visibility and image quality by two experienced radiologists (1 and 6years of experience). GEE with Wald test was used to compare the image quality among the four calculated high b value DWI by comparing the proportion of lesions in each model which were comparable to the acquired images. This comparison was done for all lesions and by lesion location (PZ or CG; low apical/anterior or apical/mid/base) Results: More lesions were visible on acquired b=2000s/mm2 compared to b=1000s/mm2 DWI. Calculated high b value DWI using the IVIM model had approximately the same number of lesions as acquired high b value DWI, whereas the DK model had fewer lesions than acquired images. The image quality of calculated high b value DWI was comparable to that of acquired images, and the highest quality images were obtained with b1000IVIM. The image quality of calculated b1000IVIM was the same as that of acquired DWI in apical/mid/base (98%) locations and comparable in low apical and anterior (95.4%) locations. The image quality of calculated b2000IVIM was inferior in both apical/mid/base (86.2%) locations and comparable in low apical and anterior (83.9%) locations. Conclusion: Calculated high b value DWI obtained using IVIM model has same lesion visibility as that of acquired DWI. The image quality of calculated high b value DWI relative to corresponding acquired DWI decreases with increase in b value. | |
| 540 | |a Springer Science+Business Media New York, 2014 | ||
| 690 | 7 | |a Prostate cancer |2 nationallicence | |
| 690 | 7 | |a MRI |2 nationallicence | |
| 690 | 7 | |a Diffusion-weighted imaging |2 nationallicence | |
| 690 | 7 | |a High b value |2 nationallicence | |
| 700 | 1 | |a Grant |D Kinzya |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | |
| 700 | 1 | |a Agarwal |D Harsh |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | |
| 700 | 1 | |a Shih |D Joanna |u Biometric Research Branch, Division of Cancer Treatment and Diagnosis, NCI, NIH, Bethesda, MD, USA |4 aut | |
| 700 | 1 | |a Bernardo |D Marcelino |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | |
| 700 | 1 | |a Pang |D Yuxi |u Philips Healthcare, Cleveland, OH, USA |4 aut | |
| 700 | 1 | |a Daar |D Dagane |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | |
| 700 | 1 | |a Merino |D Maria |u Laboratory of Pathology, NCI, NIH, Bethesda, MD, USA |4 aut | |
| 700 | 1 | |a Wood |D Bradford |u Clinical Center, Center for Interventional Oncology, NCI and Radiology and Imaging Sciences, NIH, Bethesda, MD, USA |4 aut | |
| 700 | 1 | |a Pinto |D Peter |u Urologic Oncology Branch, NCI, NIH, Bethesda, MD, USA |4 aut | |
| 700 | 1 | |a Choyke |D Peter |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | |
| 700 | 1 | |a Turkbey |D Baris |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | |
| 773 | 0 | |t Abdominal Imaging |d Springer US; http://www.springer-ny.com |g 40/3(2015-03-01), 578-586 |x 0942-8925 |q 40:3<578 |1 2015 |2 40 |o 261 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00261-014-0246-2 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s00261-014-0246-2 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Grant |D Kinzya |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Agarwal |D Harsh |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Shih |D Joanna |u Biometric Research Branch, Division of Cancer Treatment and Diagnosis, NCI, NIH, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Bernardo |D Marcelino |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Pang |D Yuxi |u Philips Healthcare, Cleveland, OH, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Daar |D Dagane |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Merino |D Maria |u Laboratory of Pathology, NCI, NIH, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Wood |D Bradford |u Clinical Center, Center for Interventional Oncology, NCI and Radiology and Imaging Sciences, NIH, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Pinto |D Peter |u Urologic Oncology Branch, NCI, NIH, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Choyke |D Peter |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Turkbey |D Baris |u Molecular Imaging Program, National Cancer Institute (NCI), NIH 10 Center Dr, MSC 1182, Bldg 10, Room B3B85, 20892-1088, Bethesda, MD, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Abdominal Imaging |d Springer US; http://www.springer-ny.com |g 40/3(2015-03-01), 578-586 |x 0942-8925 |q 40:3<578 |1 2015 |2 40 |o 261 | ||