<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605494339</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100525.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00261-014-0305-8</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00261-014-0305-8</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Garra</subfield>
   <subfield code="D">Brian</subfield>
   <subfield code="u">Washington DC VA Medical Center, Washington, DC, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Elastography: history, principles, and technique comparison</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Brian Garra]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Elastography is a relatively new imaging technology that creates images of tissue stiffness. It can be thought of an extension of the ancient technique of palpation but it gives better spatial localization information and is less subjective. Two main types of elastography are currently in use, strain elastography where the tissue displacement in response to gentle pressure is used to compute and image tissue strain, and shear wave elastography where the speed of shear waves traversing tissue is measured and used to create an image of tissue stiffness. Each method has advantages and disadvantages but generally strain imaging is excellent for focal lesions and shear wave imaging, being more quantitative, is best for diffuse organ diseases. Strain imaging requires additional training in acquisition technique to obtain high quality images. Pitfalls to avoid and tips for good images are provided. Improvements in strain imaging are focused on better quality indicators and better methods for quantification. Improvements in shear wave imaging will be higher frame rates, greater accuracy in focal lesions, and making results more comparable between different ultrasound systems. Both methods will continue to improve and will provide ever more powerful new tools for diagnosis of diffuse and focal diseases.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media New York (outside the USA), 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Elastography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Elasticity</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Shear wave</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Ultrasound</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Breast</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Thyroid</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lymph node</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Abdominal Imaging</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">40/4(2015-04-01), 680-697</subfield>
   <subfield code="x">0942-8925</subfield>
   <subfield code="q">40:4&lt;680</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">40</subfield>
   <subfield code="o">261</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00261-014-0305-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00261-014-0305-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Garra</subfield>
   <subfield code="D">Brian</subfield>
   <subfield code="u">Washington DC VA Medical Center, Washington, DC, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Abdominal Imaging</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">40/4(2015-04-01), 680-697</subfield>
   <subfield code="x">0942-8925</subfield>
   <subfield code="q">40:4&lt;680</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">40</subfield>
   <subfield code="o">261</subfield>
  </datafield>
 </record>
</collection>
