Comparison of intrahepatic vein-to-liver parenchyma and intercostal muscle-to-liver parenchyma strain ratios in the assessment of liver fibrosis: which one should we use?
Gespeichert in:
Verfasser / Beitragende:
[Bahri Altiparmak, Mehmet Nural, Ramazan Aydin, Murat Danaci]
Ort, Verlag, Jahr:
2015
Enthalten in:
Abdominal Imaging, 40/4(2015-04-01), 730-737
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605494355 | ||
| 003 | CHVBK | ||
| 005 | 20210128100525.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20150401xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s00261-014-0294-7 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s00261-014-0294-7 | ||
| 245 | 0 | 0 | |a Comparison of intrahepatic vein-to-liver parenchyma and intercostal muscle-to-liver parenchyma strain ratios in the assessment of liver fibrosis: which one should we use? |h [Elektronische Daten] |c [Bahri Altiparmak, Mehmet Nural, Ramazan Aydin, Murat Danaci] |
| 520 | 3 | |a Purpose: The aims of this study were to investigate whether there is a difference in diagnostic value between vein to parenchyma strain ratio (VPSR) and muscle to parenchyma strain ratio (MPSR). Methods: VPSR and MPSR were calculated via sonoelastography, and were recorded for comparison with histopathology. ROC analysis, the Mann-Whitney U test, the Kruskal-Wallis test, and Spearman's rank correlation test were used for statistical analysis. Results: The study included 59 cases of individuals who underwent biopsy (29 women, 30 men). When the threshold value for VPSR was set at 3.23, the sensitivity was 96.2% and the specificity was 83.3% (p<0.001, F≥1). When the threshold value was set at 3.01 for MPR, the sensitivity was 88.7% and the specificity was 83.3% (p<0.001, F≥1). The areas under the curve values were VPSR 0.95 and MPSR 0.92 for F≥1, VPSR 0.94 and MPSR 0.92 for F≥2, and VPSR 1.00 and MPSR 0.76 for F=3 (p<0.001). The Spearman's correlation coefficient was 0.75, and a high positive concordance was found between VPSR and MPSR (p<0.001). Conclusions: In this study, a high positive correlation was observed between two strain ratios, and VPSR was found to be more reliable than MPSR in determining liver fibrosis. | |
| 540 | |a Springer Science+Business Media New York, 2014 | ||
| 690 | 7 | |a Liver fibrosis |2 nationallicence | |
| 690 | 7 | |a Percutaneous biopsy |2 nationallicence | |
| 690 | 7 | |a Sonoelastography |2 nationallicence | |
| 690 | 7 | |a Strain ratio |2 nationallicence | |
| 700 | 1 | |a Altiparmak |D Bahri |u Department of Radiology, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey |4 aut | |
| 700 | 1 | |a Nural |D Mehmet |u Department of Radiology, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey |4 aut | |
| 700 | 1 | |a Aydin |D Ramazan |u Clinic of Radiology, Kırıkkale Yüksek İhtisas Hospital, Kirikkale, Turkey |4 aut | |
| 700 | 1 | |a Danaci |D Murat |u Department of Radiology, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey |4 aut | |
| 773 | 0 | |t Abdominal Imaging |d Springer US; http://www.springer-ny.com |g 40/4(2015-04-01), 730-737 |x 0942-8925 |q 40:4<730 |1 2015 |2 40 |o 261 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00261-014-0294-7 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a review-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s00261-014-0294-7 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Altiparmak |D Bahri |u Department of Radiology, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Nural |D Mehmet |u Department of Radiology, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Aydin |D Ramazan |u Clinic of Radiology, Kırıkkale Yüksek İhtisas Hospital, Kirikkale, Turkey |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Danaci |D Murat |u Department of Radiology, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Abdominal Imaging |d Springer US; http://www.springer-ny.com |g 40/4(2015-04-01), 730-737 |x 0942-8925 |q 40:4<730 |1 2015 |2 40 |o 261 | ||