Shortened breath-hold contrast-enhanced MRI of the liver using a new parallel imaging technique, CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration): a comparison with conventional GRAPPA technique

Verfasser / Beitragende:
[Masaki Ogawa, Tatsuya Kawai, Hirohito Kan, Susumu Kobayashi, Yoshihiro Akagawa, Kazushi Suzuki, Shunsuke Nojiri, Yoshiyuki Ozawa, Yuta Shibamoto]
Ort, Verlag, Jahr:
2015
Enthalten in:
Abdominal Imaging, 40/8(2015-10-01), 3091-3098
Format:
Artikel (online)
ID: 605494398
LEADER caa a22 4500
001 605494398
003 CHVBK
005 20210128100525.0
007 cr unu---uuuuu
008 210128e20151001xx s 000 0 eng
024 7 0 |a 10.1007/s00261-015-0491-z  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s00261-015-0491-z 
245 0 0 |a Shortened breath-hold contrast-enhanced MRI of the liver using a new parallel imaging technique, CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration): a comparison with conventional GRAPPA technique  |h [Elektronische Daten]  |c [Masaki Ogawa, Tatsuya Kawai, Hirohito Kan, Susumu Kobayashi, Yoshihiro Akagawa, Kazushi Suzuki, Shunsuke Nojiri, Yoshiyuki Ozawa, Yuta Shibamoto] 
520 3 |a Purpose: We examined whether the shortened breath-hold 3-dimensional volumetric interpolated breath-hold examination (3D-VIBE) sequence for high acceleration factor (AF) using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) could substitute for the conventional sequence using generalized autocalibrating partially parallel acquisition (GRAPPA) in patients undergoing routine gadoxetic acid-enhanced liver MRI. Materials and methods: Thirty patients with clinically suspected focal liver lesions were scanned using 3D-VIBE sequences with GRAPPA with AF=2 and AF=4 and CAIPIRINHA with AF=4 (acquisition times: 21, 14, and 12s, respectively) during the hepatobiliary phase. Visual evaluations using a 3- or 5-point scale and signal-to-noise ratio (SNR) analysis were performed for the 3 sequences. Results: For CAIPIRINHA with AF=4, there was significantly less image noise in both visual evaluation and SNR analysis and fewer parallel imaging artifacts than for GRAPPA with AF=4 (P<0.0005); it was equal to GRAPPA with AF=2 and had fewer motion artifacts than GRAPPA with AF=2 and 4 (P<0.0012). The liver edge sharpness and hepatic vessel clarity, lesion conspicuity, and overall image quality were rated significantly higher with CAIPIRINHA with AF=4 than GRAPPA with AF=2 and AF=4 (P<0.009). For GRAPPA with AF=4, lesion conspicuity and overall image quality were rated significantly lower than for GRAPPA with AF=2 (P<0.012). Conclusion: The shortened breath-hold 3D-VIBE sequence using the new CAIPIRINHA technique with a high AF of 4 was superior to the conventional GRAPPA sequence. The shortened breath-hold sequence using GRAPPA with a high AF of 4 worsened the image quality and lesion conspicuity. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)  |2 nationallicence 
690 7 |a Short breath hold  |2 nationallicence 
690 7 |a 3-Dimensional volumetric interpolated breath-hold examination (3D-VIBE)  |2 nationallicence 
690 7 |a Parallel imaging technique  |2 nationallicence 
690 7 |a High acceleration factor (AF)  |2 nationallicence 
690 7 |a Gadoxetic acid-enhanced liver MRI  |2 nationallicence 
700 1 |a Ogawa  |D Masaki  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
700 1 |a Kawai  |D Tatsuya  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
700 1 |a Kan  |D Hirohito  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
700 1 |a Kobayashi  |D Susumu  |u Department of Radiology, Toyokawa City Hospital, Toyokawa, Japan  |4 aut 
700 1 |a Akagawa  |D Yoshihiro  |u Department of Radiology, Toyokawa City Hospital, Toyokawa, Japan  |4 aut 
700 1 |a Suzuki  |D Kazushi  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
700 1 |a Nojiri  |D Shunsuke  |u Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan  |4 aut 
700 1 |a Ozawa  |D Yoshiyuki  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
700 1 |a Shibamoto  |D Yuta  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
773 0 |t Abdominal Imaging  |d Springer US; http://www.springer-ny.com  |g 40/8(2015-10-01), 3091-3098  |x 0942-8925  |q 40:8<3091  |1 2015  |2 40  |o 261 
856 4 0 |u https://doi.org/10.1007/s00261-015-0491-z  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s00261-015-0491-z  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ogawa  |D Masaki  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kawai  |D Tatsuya  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kan  |D Hirohito  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kobayashi  |D Susumu  |u Department of Radiology, Toyokawa City Hospital, Toyokawa, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Akagawa  |D Yoshihiro  |u Department of Radiology, Toyokawa City Hospital, Toyokawa, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Suzuki  |D Kazushi  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Nojiri  |D Shunsuke  |u Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ozawa  |D Yoshiyuki  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Shibamoto  |D Yuta  |u Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, 467-8601, Nagoya, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Abdominal Imaging  |d Springer US; http://www.springer-ny.com  |g 40/8(2015-10-01), 3091-3098  |x 0942-8925  |q 40:8<3091  |1 2015  |2 40  |o 261