Motion artifacts in kidney stone imaging using single-source and dual-source dual-energy CT scanners: a phantom study

Verfasser / Beitragende:
[El-Sayed Ibrahim, Joseph Cernigliaro, Robert Pooley, James Williams, William Haley]
Ort, Verlag, Jahr:
2015
Enthalten in:
Abdominal Imaging, 40/8(2015-10-01), 3161-3167
Format:
Artikel (online)
ID: 605494851
LEADER caa a22 4500
001 605494851
003 CHVBK
005 20210128100528.0
007 cr unu---uuuuu
008 210128e20151001xx s 000 0 eng
024 7 0 |a 10.1007/s00261-015-0530-9  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s00261-015-0530-9 
245 0 0 |a Motion artifacts in kidney stone imaging using single-source and dual-source dual-energy CT scanners: a phantom study  |h [Elektronische Daten]  |c [El-Sayed Ibrahim, Joseph Cernigliaro, Robert Pooley, James Williams, William Haley] 
520 3 |a Purpose: Dual-energy computed tomography (DECT) has shown the capability of differentiating uric acid (UA) from non-UA stones with 90-100% accuracy. With the invention of dual-source (DS) scanners, both low- and high-energy images are acquired simultaneously. However, DECT can also be performed by sequential acquisition of both images on single-source (SS) scanners. The objective of this study is to investigate the effects of motion artifacts on stone classification using both SS-DECT and DS-DECT. Methods: 114 kidney stones of different types and sizes were imaged on both DS-DECT and SS-DECT scanners with tube voltages of 80 and 140kVp with and without induced motion. Postprocessing was conducted to create material-specific images from corresponding low- and high-energy images. The dual-energy ratio (DER) and stone material were determined and compared among different scans. Results: For the motionless scans, all stones were correctly classified with SS-DECT, while two cystine stones were misclassified with DS-DECT. When motion was induced, 94% of the stones were misclassified with SS-DECT versus 11% with DS-DECT (P<0.0001). Stone size was not a factor in stone misclassification under motion. Stone type was not a factor in stone misclassification under motion with SS-DECT, although with DS-DECT, cystine showed higher number of stone misclassification. Conclusions: Motion artifacts could result in stone misclassification in DECT. This effect is more pronounced in SS-DECT versus DS-DECT, especially if stones of different types lie in close proximity to each other. Further, possible misinterpretation of the number of stones (i.e., missing one, or thinking that there are two) in DS-DECT could be a potentially significant problem. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a Motion artifacts  |2 nationallicence 
690 7 |a Dual-energy computed tomography  |2 nationallicence 
690 7 |a Kidney stones  |2 nationallicence 
690 7 |a Nephrolithiasis  |2 nationallicence 
700 1 |a Ibrahim  |D El-Sayed  |u Mayo Clinic, 4500 San Pablo Rd, 32224, Jacksonville, FL, USA  |4 aut 
700 1 |a Cernigliaro  |D Joseph  |u Mayo Clinic, 4500 San Pablo Rd, 32224, Jacksonville, FL, USA  |4 aut 
700 1 |a Pooley  |D Robert  |u Mayo Clinic, 4500 San Pablo Rd, 32224, Jacksonville, FL, USA  |4 aut 
700 1 |a Williams  |D James  |u Indiana University, 340W 10th St, 46202, Indianapolis, IN, USA  |4 aut 
700 1 |a Haley  |D William  |u Mayo Clinic, 4500 San Pablo Rd, 32224, Jacksonville, FL, USA  |4 aut 
773 0 |t Abdominal Imaging  |d Springer US; http://www.springer-ny.com  |g 40/8(2015-10-01), 3161-3167  |x 0942-8925  |q 40:8<3161  |1 2015  |2 40  |o 261 
856 4 0 |u https://doi.org/10.1007/s00261-015-0530-9  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s00261-015-0530-9  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ibrahim  |D El-Sayed  |u Mayo Clinic, 4500 San Pablo Rd, 32224, Jacksonville, FL, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Cernigliaro  |D Joseph  |u Mayo Clinic, 4500 San Pablo Rd, 32224, Jacksonville, FL, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Pooley  |D Robert  |u Mayo Clinic, 4500 San Pablo Rd, 32224, Jacksonville, FL, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Williams  |D James  |u Indiana University, 340W 10th St, 46202, Indianapolis, IN, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Haley  |D William  |u Mayo Clinic, 4500 San Pablo Rd, 32224, Jacksonville, FL, USA  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Abdominal Imaging  |d Springer US; http://www.springer-ny.com  |g 40/8(2015-10-01), 3161-3167  |x 0942-8925  |q 40:8<3161  |1 2015  |2 40  |o 261