<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605495319</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100530.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150601xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00261-014-0271-1</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00261-014-0271-1</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Reducing the radiation dose for computed tomography colonography using model-based iterative reconstruction</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Patrick Millerd, Robert Paden, Jeffrey Lund, Amy Hara, Wendy Stiles, Miao He, Qing Wu, C. Daniel Johnson]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Purpose: To determine whether radiation doses during computed tomography (CT) colonography (CTC) can be further reduced while maintaining image quality using model-based iterative reconstruction (MBIR). Methods: Twenty patients underwent CTC at a standard dose in supine and prone positions and at a reduced dose in the supine position. All other scan parameters (except noise index) were held constant. Acquisitions were reconstructed using 3 algorithms: filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and MBIR. Noise was assessed quantitatively by comparing the SD in Hounsfield units at 5 standard locations. Qualitative assessment was made by 2 experienced radiologists blinded to technique who subjectively scored image quality, noise, and sharpness (from 0 to 4). Results: The standard-dose and reduced-dose CT dose index/dose-length product were 6.7/328 and 2.7mGy/129mGy-cm, respectively (60% reduction). Measured mean noise level increased from the standard to the reduced dose (FBP, from 58.6 to 97.2; ASIR from 35.8 to 60.6; and MBIR from 16.6 to 21.9). MBIR had significantly less noise than ASIR on 2-dimensional images at both standard and reduced doses (P&lt;.01). Conclusions: Radiation dose in CTC using MBIR can be reduced by 60% while maintaining image quality and reducing image noise.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media New York, 2014</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Adaptive statistical iterative reconstruction</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Computed tomography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">CT colonography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Iterative reconstruction</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Model-based iterative reconstruction</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Reduced dose</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">ASIR : Adaptive statistical iterative reconstruction</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">BMI : Body mass index (weight in kg divided by height in m2 [kg/m2])</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">CT : Computed tomography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">CTC : Computed tomography colonography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">DLP : Dose-length product</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">FBP : Filtered back projection</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">HIPAA : Health Insurance Portability and Accountability Act</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">kVp : Kilovolts peak</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">mAs : Milliamperes-second</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">MBIR : Model-based iterative reconstruction</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">MDCT : Multidetector computed tomography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">mSv : Millisievert</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Millerd</subfield>
   <subfield code="D">Patrick</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Paden</subfield>
   <subfield code="D">Robert</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lund</subfield>
   <subfield code="D">Jeffrey</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hara</subfield>
   <subfield code="D">Amy</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Stiles</subfield>
   <subfield code="D">Wendy</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">He</subfield>
   <subfield code="D">Miao</subfield>
   <subfield code="u">Arizona State University, Tempe, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Wu</subfield>
   <subfield code="D">Qing</subfield>
   <subfield code="u">Division of Health Sciences Research, Mayo Clinic, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Daniel Johnson</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Abdominal Imaging</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">40/5(2015-06-01), 1183-1189</subfield>
   <subfield code="x">0942-8925</subfield>
   <subfield code="q">40:5&lt;1183</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">40</subfield>
   <subfield code="o">261</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00261-014-0271-1</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00261-014-0271-1</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Millerd</subfield>
   <subfield code="D">Patrick</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Paden</subfield>
   <subfield code="D">Robert</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lund</subfield>
   <subfield code="D">Jeffrey</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hara</subfield>
   <subfield code="D">Amy</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Stiles</subfield>
   <subfield code="D">Wendy</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">He</subfield>
   <subfield code="D">Miao</subfield>
   <subfield code="u">Arizona State University, Tempe, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wu</subfield>
   <subfield code="D">Qing</subfield>
   <subfield code="u">Division of Health Sciences Research, Mayo Clinic, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Daniel Johnson</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Department of Radiology, Mayo Clinic, 13400 E Shea Blvd, 85259, Scottsdale, AZ, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Abdominal Imaging</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">40/5(2015-06-01), 1183-1189</subfield>
   <subfield code="x">0942-8925</subfield>
   <subfield code="q">40:5&lt;1183</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">40</subfield>
   <subfield code="o">261</subfield>
  </datafield>
 </record>
</collection>
