Conversion of chemical scrubbers to biotrickling filters for VOCs and H2S treatment at low contact times
Gespeichert in:
Verfasser / Beitragende:
[Alfredo Santos, Xavier Guimerà, Antonio Dorado, Xavier Gamisans, David Gabriel]
Ort, Verlag, Jahr:
2015
Enthalten in:
Applied Microbiology and Biotechnology, 99/1(2015-01-01), 67-76
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605497915 | ||
| 003 | CHVBK | ||
| 005 | 20210128100543.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20150101xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s00253-014-5796-2 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s00253-014-5796-2 | ||
| 245 | 0 | 0 | |a Conversion of chemical scrubbers to biotrickling filters for VOCs and H2S treatment at low contact times |h [Elektronische Daten] |c [Alfredo Santos, Xavier Guimerà, Antonio Dorado, Xavier Gamisans, David Gabriel] |
| 520 | 3 | |a The purpose of this work was to evaluate the technical and economical feasibility of converting three chemical scrubbers in series to biotrickling filters (BTFs) for the simultaneous removal of H2S and volatile organic compounds (VOCs). The conversion of the full-scale scrubbers was based on previous conversion protocols. Conversion mainly required replacing the original carrier material and recycle pumps as well as modifying the controls and operation of the reactors. Complete removal of H2S and VOCs on a routine basis was reached at neutral pH in a longer period of time compared to previous conversions reported. Biotrickling filters operated at a gas contact time of about 1.4s per reactor and at pH controlled between 6.5 and 6.8. Inlet average concentrations below 10 ppmv of H2S and below 5 ppmv for VOCs were often completely removed. The first and second bioreactors played a primary role in H2S removal. Year-round operation of the biotrickling filters proved the ability of the system to handle progressive load increases of H2S and VOCs. However, fast, sudden load changes often lead to reduced removal efficiencies. Odor analyses showed average removal efficiencies above 80%. Gas chromatography-mass spectrometry of selected samples showed that outlet odor concentration was due to limited removal of VOCs. The conversion showed was economically viable taking into account the theoretical consumption of chemicals needed for the absorption and oxidation of both H2S and VOCs. | |
| 540 | |a Springer-Verlag Berlin Heidelberg, 2014 | ||
| 690 | 7 | |a Chemical scrubbers' conversion |2 nationallicence | |
| 690 | 7 | |a Biotrickling filterm |2 nationallicence | |
| 690 | 7 | |a H2S |2 nationallicence | |
| 690 | 7 | |a VOCs |2 nationallicence | |
| 690 | 7 | |a Neutral pH operation |2 nationallicence | |
| 700 | 1 | |a Santos |D Alfredo |u Department of Chemical Engineering, School of Engineering, Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain |4 aut | |
| 700 | 1 | |a Guimerà |D Xavier |u Department of Mining Engineering and Natural Resources, Universitat Politècnica de Catalunya, Avinguda de les Bases de Manresa 61-73, 08240, Manresa, Spain |4 aut | |
| 700 | 1 | |a Dorado |D Antonio |u Department of Mining Engineering and Natural Resources, Universitat Politècnica de Catalunya, Avinguda de les Bases de Manresa 61-73, 08240, Manresa, Spain |4 aut | |
| 700 | 1 | |a Gamisans |D Xavier |u Department of Mining Engineering and Natural Resources, Universitat Politècnica de Catalunya, Avinguda de les Bases de Manresa 61-73, 08240, Manresa, Spain |4 aut | |
| 700 | 1 | |a Gabriel |D David |u Department of Chemical Engineering, School of Engineering, Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain |4 aut | |
| 773 | 0 | |t Applied Microbiology and Biotechnology |d Springer Berlin Heidelberg |g 99/1(2015-01-01), 67-76 |x 0175-7598 |q 99:1<67 |1 2015 |2 99 |o 253 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00253-014-5796-2 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s00253-014-5796-2 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Santos |D Alfredo |u Department of Chemical Engineering, School of Engineering, Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Guimerà |D Xavier |u Department of Mining Engineering and Natural Resources, Universitat Politècnica de Catalunya, Avinguda de les Bases de Manresa 61-73, 08240, Manresa, Spain |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Dorado |D Antonio |u Department of Mining Engineering and Natural Resources, Universitat Politècnica de Catalunya, Avinguda de les Bases de Manresa 61-73, 08240, Manresa, Spain |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Gamisans |D Xavier |u Department of Mining Engineering and Natural Resources, Universitat Politècnica de Catalunya, Avinguda de les Bases de Manresa 61-73, 08240, Manresa, Spain |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Gabriel |D David |u Department of Chemical Engineering, School of Engineering, Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Applied Microbiology and Biotechnology |d Springer Berlin Heidelberg |g 99/1(2015-01-01), 67-76 |x 0175-7598 |q 99:1<67 |1 2015 |2 99 |o 253 | ||