The relative trending accuracy of noninvasive continuous hemoglobin monitoring during hemodialysis in critically ill patients

Verfasser / Beitragende:
[Hiroshi Yamada, Minako Saeki, Junko Ito, Kazuhiro Kawada, Aya Higurashi, Hiromi Funakoshi, Kohji Takeda]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/1(2015-02-01), 107-112
Format:
Artikel (online)
ID: 605509557
LEADER caa a22 4500
001 605509557
003 CHVBK
005 20210128100641.0
007 cr unu---uuuuu
008 210128e20150201xx s 000 0 eng
024 7 0 |a 10.1007/s10877-014-9574-6  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10877-014-9574-6 
245 0 4 |a The relative trending accuracy of noninvasive continuous hemoglobin monitoring during hemodialysis in critically ill patients  |h [Elektronische Daten]  |c [Hiroshi Yamada, Minako Saeki, Junko Ito, Kazuhiro Kawada, Aya Higurashi, Hiromi Funakoshi, Kohji Takeda] 
520 3 |a The pulse CO-Oximeter (Radical-7; Masimo Corp., Irvine, CA) is a multi-wavelength spectrophotometric method for noninvasive continuous monitoring of hemoglobin (SpHb). Because evaluating the relative change in blood volume (ΔBV) is crucial to avoid hypovolemia and hypotension during hemodialysis, it would be of great clinical benefit if ΔBV could be estimated by measurement of SpHb during hemodialysis. The capability of the pulse CO-Oximeter to monitor ΔBV depends on the relative trending accuracy of SpHb. The purpose of the current study was to evaluate the relative trending accuracy of SpHb by the pulse CO-Oximeter using Crit-Line as a reference device. In 12 patients who received hemodialysis (total 22 sessions) in the intensive care unit, ΔBV was determined from SpHb. Relative changes in blood volume determined from SpHb were calculated according to the equation: ΔBV(SpHb)=[starting SpHb]/[current SpHb]−1. The absolute values of SpHb and hematocrit measured by Crit-Line (CL-Hct) showed poor correlation. On the contrary, linear regression analysis showed good correlation between ΔBV(SpHb) and the relative change in blood volume measured by Crit-Line [ΔBV(CL-Hct)] (r=0.83; P≤0.001). Bland-Altman analysis also revealed good agreement between ΔBV(SpHb) and ΔBV(CL-Hct) (bias, −0.77%; precision, 3.41%). Polar plot analysis revealed good relative trending accuracy of SpHb with an angular bias of 4.1° and radial limits of agreement of 24.4° (upper) and −16.2° (lower). The results of the current study indicate that SpHb measurement with the pulse CO-Oximeter has good relative trending accuracy. 
540 |a Springer Science+Business Media New York, 2014 
690 7 |a SpHb  |2 nationallicence 
690 7 |a Pulse CO-oximetry  |2 nationallicence 
690 7 |a Noninvasive continuous hemoglobin monitoring  |2 nationallicence 
690 7 |a Polar plot analysis  |2 nationallicence 
690 7 |a Relative trending accuracy  |2 nationallicence 
690 7 |a Hemodialysis  |2 nationallicence 
700 1 |a Yamada  |D Hiroshi  |u Critical Care Division, Fujisawa City Hospital, 2-6-1 Fujisawa, 251-8550, Fujisawa, Kanagawa, Japan  |4 aut 
700 1 |a Saeki  |D Minako  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
700 1 |a Ito  |D Junko  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
700 1 |a Kawada  |D Kazuhiro  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
700 1 |a Higurashi  |D Aya  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
700 1 |a Funakoshi  |D Hiromi  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
700 1 |a Takeda  |D Kohji  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
773 0 |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/1(2015-02-01), 107-112  |x 1387-1307  |q 29:1<107  |1 2015  |2 29  |o 10877 
856 4 0 |u https://doi.org/10.1007/s10877-014-9574-6  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10877-014-9574-6  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Yamada  |D Hiroshi  |u Critical Care Division, Fujisawa City Hospital, 2-6-1 Fujisawa, 251-8550, Fujisawa, Kanagawa, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Saeki  |D Minako  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ito  |D Junko  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kawada  |D Kazuhiro  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Higurashi  |D Aya  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Funakoshi  |D Hiromi  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Takeda  |D Kohji  |u Department of Anesthesiology and Critical Care Medicine, Fujisawa City Hospital, Fujisawa, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/1(2015-02-01), 107-112  |x 1387-1307  |q 29:1<107  |1 2015  |2 29  |o 10877