Capability of a neck worn device to measure sleep/wake, airway position, and differentiate benign snoring from obstructive sleep apnea

Verfasser / Beitragende:
[Daniel Levendowski, Bratislav Veljkovic, Sean Seagraves, Philip Westbrook]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/1(2015-02-01), 53-64
Format:
Artikel (online)
ID: 605509573
LEADER caa a22 4500
001 605509573
003 CHVBK
005 20210128100641.0
007 cr unu---uuuuu
008 210128e20150201xx s 000 0 eng
024 7 0 |a 10.1007/s10877-014-9569-3  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10877-014-9569-3 
245 0 0 |a Capability of a neck worn device to measure sleep/wake, airway position, and differentiate benign snoring from obstructive sleep apnea  |h [Elektronische Daten]  |c [Daniel Levendowski, Bratislav Veljkovic, Sean Seagraves, Philip Westbrook] 
520 3 |a To evaluate the accuracy of a neck-worn device in measuring sleep/wake, detecting supine airway position, and using loud snoring to screen for obstructive sleep apnea. Study A included 20 subjects who wore the neck-device during polysomnography (PSG), with 31 records obtained from diagnostic and split-night studies. Study B included 24 community-based snorers studied in-home for up to three-nights with obstructive sleep apnea (OSA) severity measured with a validated Level III recorder. The accuracy of neck actigraphy-based sleep/wake was measured by assessing sleep efficiency (SE). Differences in sleep position measured at the chest and neck during PSG were compared to video-editing. Loud snoring acquired with an acoustic microphone was compared to the apnea-hypopnea index (AHI) by- and acrosspositions. Over-reported SE by neck actigraphy was inversely related to OSA severity. Measurement of neck and chest supine position were highly correlated with video-edits (r=0.93, 0.78). Chest was bias toward over-estimating supine time while the majority of neck-device supine position errors occurred during CPAP titrations. Snoring was highly correlated with the overall, supine, and non-supine PSG-AHI (r=0.79, 0.74, 0.83) and was both sensitive and specific in detecting overall, supine, and non-supine PSGAHI >10 (sensitivity=81, 88, 82%; specificity=87, 79, 100%). At home sleep testing-AHI>10, the sensitivity and specificity of loud snoring was superior when users were predominantly non-supine as compared to baseline (sensitivity=100, 92%; specificity=88, 77%). Neck actigraphy appears capable of estimating sleep/wake. The accuracy of supine airway detection with the neck-device warrants further investigation. Measurement of loud snoring appears to provide a screening tool for differentiating positional apneic and benign snorers. 
540 |a The Author(s), 2014 
690 7 |a OSA  |2 nationallicence 
690 7 |a Positional  |2 nationallicence 
690 7 |a Snoring  |2 nationallicence 
690 7 |a Screening  |2 nationallicence 
690 7 |a Actigraphy  |2 nationallicence 
690 7 |a Validation  |2 nationallicence 
700 1 |a Levendowski  |D Daniel  |u Advanced Brain Monitoring Inc., Carlsbad, CA, USA  |4 aut 
700 1 |a Veljkovic  |D Bratislav  |u Advanced Brain Monitoring Inc., Carlsbad, CA, USA  |4 aut 
700 1 |a Seagraves  |D Sean  |u Advanced Brain Monitoring Inc., Carlsbad, CA, USA  |4 aut 
700 1 |a Westbrook  |D Philip  |u Advanced Brain Monitoring Inc., Carlsbad, CA, USA  |4 aut 
773 0 |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/1(2015-02-01), 53-64  |x 1387-1307  |q 29:1<53  |1 2015  |2 29  |o 10877 
856 4 0 |u https://doi.org/10.1007/s10877-014-9569-3  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10877-014-9569-3  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Levendowski  |D Daniel  |u Advanced Brain Monitoring Inc., Carlsbad, CA, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Veljkovic  |D Bratislav  |u Advanced Brain Monitoring Inc., Carlsbad, CA, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Seagraves  |D Sean  |u Advanced Brain Monitoring Inc., Carlsbad, CA, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Westbrook  |D Philip  |u Advanced Brain Monitoring Inc., Carlsbad, CA, USA  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/1(2015-02-01), 53-64  |x 1387-1307  |q 29:1<53  |1 2015  |2 29  |o 10877