Detection of endobronchial intubation by monitoring the CO2 level above the endotracheal cuff

Verfasser / Beitragende:
[Shai Efrati, Israel Deutsch, Nathan Weksler, Gabriel Gurman]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/1(2015-02-01), 19-23
Format:
Artikel (online)
ID: 605509689
LEADER caa a22 4500
001 605509689
003 CHVBK
005 20210128100642.0
007 cr unu---uuuuu
008 210128e20150201xx s 000 0 eng
024 7 0 |a 10.1007/s10877-014-9583-5  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10877-014-9583-5 
245 0 0 |a Detection of endobronchial intubation by monitoring the CO2 level above the endotracheal cuff  |h [Elektronische Daten]  |c [Shai Efrati, Israel Deutsch, Nathan Weksler, Gabriel Gurman] 
520 3 |a Early detection of accidental endobronchial intubation (EBI) is still an unsolved problem in anesthesia and critical care daily practice. The aim of this study was to evaluate the ability of monitoring above cuff CO2 to detect EBI (the working hypothesis was that the origin of CO2 is from the unventilated, but still perfused, lung). Six goats were intubated under general anesthesia and the ETT positioning was verified by a flexible bronchoscope. The AnapnoGuard system, already successfully used to detect air leak around the ETT cuff, was used for continuous monitoring of above-the-cuff CO2 level. When the ETT distal tip was located in the trachea, with an average cuff pressure of 15mmHg, absence of CO2 above the cuff was observed. The ETT was then deliberately advanced into one of the main bronchi under flexible bronchoscopic vision. In all six cases the immediate presence of CO2 above the cuff was identified. Further automatic inflation of the cuff, up to a level of 27mmHg, did not affect the above-the-cuff measured CO2 level. Withdrawal of the ETT and repositioning of its distal tip in mid-trachea caused the disappearance of CO2 above the cuff in a maximum of 3min, confirming the absence of air leak and the correct positioning of the ETT. Our results suggest that measurement of the above-the-cuff CO2 level could offer a reliable, on-line solution for early identification of accidental EBI. Further studies are planned to validate the efficacy of the method in a clinical setup. 
540 |a Springer Science+Business Media New York, 2014 
690 7 |a Endobronchial  |2 nationallicence 
690 7 |a Intubation  |2 nationallicence 
690 7 |a One lung  |2 nationallicence 
690 7 |a CO2  |2 nationallicence 
690 7 |a Endotracheal tube  |2 nationallicence 
700 1 |a Efrati  |D Shai  |u Research and Development Unit, Assaf Harofeh Medical Center, Affiliated with the Sackler School of Medicine, Tel-Aviv University, 70300, Zerifin, Israel  |4 aut 
700 1 |a Deutsch  |D Israel  |u Hospitech Respiration Ltd., Petah Tikva, Israel  |4 aut 
700 1 |a Weksler  |D Nathan  |u Division of Anesthesiology and Critical Care, Myney Hayeshuah, Bnei Brak, Ben-Gurion University of the Negev, Beersheba, Israel  |4 aut 
700 1 |a Gurman  |D Gabriel  |u Division of Anesthesiology and Critical Care, Myney Hayeshuah, Bnei Brak, Ben-Gurion University of the Negev, Beersheba, Israel  |4 aut 
773 0 |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/1(2015-02-01), 19-23  |x 1387-1307  |q 29:1<19  |1 2015  |2 29  |o 10877 
856 4 0 |u https://doi.org/10.1007/s10877-014-9583-5  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10877-014-9583-5  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Efrati  |D Shai  |u Research and Development Unit, Assaf Harofeh Medical Center, Affiliated with the Sackler School of Medicine, Tel-Aviv University, 70300, Zerifin, Israel  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Deutsch  |D Israel  |u Hospitech Respiration Ltd., Petah Tikva, Israel  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Weksler  |D Nathan  |u Division of Anesthesiology and Critical Care, Myney Hayeshuah, Bnei Brak, Ben-Gurion University of the Negev, Beersheba, Israel  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Gurman  |D Gabriel  |u Division of Anesthesiology and Critical Care, Myney Hayeshuah, Bnei Brak, Ben-Gurion University of the Negev, Beersheba, Israel  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/1(2015-02-01), 19-23  |x 1387-1307  |q 29:1<19  |1 2015  |2 29  |o 10877