A substitution method to improve completeness of events documentation in anesthesia records
Gespeichert in:
Verfasser / Beitragende:
[Antoine Lamer, Julien De Jonckheere, Romaric Marcilly, Benoît Tavernier, Benoît Vallet, Mathieu Jeanne, Régis Logier]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/6(2015-12-01), 741-747
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605509840 | ||
| 003 | CHVBK | ||
| 005 | 20210128100643.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20151201xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s10877-015-9661-3 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s10877-015-9661-3 | ||
| 245 | 0 | 2 | |a A substitution method to improve completeness of events documentation in anesthesia records |h [Elektronische Daten] |c [Antoine Lamer, Julien De Jonckheere, Romaric Marcilly, Benoît Tavernier, Benoît Vallet, Mathieu Jeanne, Régis Logier] |
| 520 | 3 | |a AIMS are optimized to find and display data and curves about one specific intervention but is not retrospective analysis on a huge volume of interventions. Such a system present two main limitation; (1) the transactional database architecture, (2) the completeness of documentation. In order to solve the architectural problem, data warehouses were developed to propose architecture suitable for analysis. However, completeness of documentation stays unsolved. In this paper, we describe a method which allows determining of substitution rules in order to detect missing anesthesia events in an anesthesia record. Our method is based on the principle that missing event could be detected using a substitution one defined as the nearest documented event. As an example, we focused on the automatic detection of the start and the end of anesthesia procedure when these events were not documented by the clinicians. We applied our method on a set of records in order to evaluate; (1) the event detection accuracy, (2) the improvement of valid records. For the year 2010-2012, we obtained event detection with a precision of 0.00 (−2.22; 2.00) min for the start of anesthesia and 0.10 (0.00; 0.35) min for the end of anesthesia. On the other hand, we increased by 21.1% the data completeness (from 80.3 to 97.2% of the total database) for the start and the end of anesthesia events. This method seems to be efficient to replace missing "start and end of anesthesia” events. This method could also be used to replace other missing time events in this particular data warehouse as well as in other kind of data warehouses. | |
| 540 | |a Springer Science+Business Media New York, 2015 | ||
| 690 | 7 | |a AIMS |2 nationallicence | |
| 690 | 7 | |a Data completeness |2 nationallicence | |
| 690 | 7 | |a Substitution rule |2 nationallicence | |
| 690 | 7 | |a Data warehouse |2 nationallicence | |
| 700 | 1 | |a Lamer |D Antoine |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | |
| 700 | 1 | |a De Jonckheere |D Julien |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | |
| 700 | 1 | |a Marcilly |D Romaric |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | |
| 700 | 1 | |a Tavernier |D Benoît |u Pôle d'Anesthésie Réanimation, University Hospital, 59000, Lille, France |4 aut | |
| 700 | 1 | |a Vallet |D Benoît |u Pôle d'Anesthésie Réanimation, University Hospital, 59000, Lille, France |4 aut | |
| 700 | 1 | |a Jeanne |D Mathieu |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | |
| 700 | 1 | |a Logier |D Régis |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | |
| 773 | 0 | |t Journal of Clinical Monitoring and Computing |d Springer Netherlands |g 29/6(2015-12-01), 741-747 |x 1387-1307 |q 29:6<741 |1 2015 |2 29 |o 10877 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s10877-015-9661-3 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s10877-015-9661-3 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Lamer |D Antoine |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a De Jonckheere |D Julien |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Marcilly |D Romaric |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Tavernier |D Benoît |u Pôle d'Anesthésie Réanimation, University Hospital, 59000, Lille, France |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Vallet |D Benoît |u Pôle d'Anesthésie Réanimation, University Hospital, 59000, Lille, France |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Jeanne |D Mathieu |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Logier |D Régis |u INSERM CIC-IT, University Hospital, 59000, Lille, France |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Journal of Clinical Monitoring and Computing |d Springer Netherlands |g 29/6(2015-12-01), 741-747 |x 1387-1307 |q 29:6<741 |1 2015 |2 29 |o 10877 | ||