A substitution method to improve completeness of events documentation in anesthesia records

Verfasser / Beitragende:
[Antoine Lamer, Julien De Jonckheere, Romaric Marcilly, Benoît Tavernier, Benoît Vallet, Mathieu Jeanne, Régis Logier]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/6(2015-12-01), 741-747
Format:
Artikel (online)
ID: 605509840
LEADER caa a22 4500
001 605509840
003 CHVBK
005 20210128100643.0
007 cr unu---uuuuu
008 210128e20151201xx s 000 0 eng
024 7 0 |a 10.1007/s10877-015-9661-3  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10877-015-9661-3 
245 0 2 |a A substitution method to improve completeness of events documentation in anesthesia records  |h [Elektronische Daten]  |c [Antoine Lamer, Julien De Jonckheere, Romaric Marcilly, Benoît Tavernier, Benoît Vallet, Mathieu Jeanne, Régis Logier] 
520 3 |a AIMS are optimized to find and display data and curves about one specific intervention but is not retrospective analysis on a huge volume of interventions. Such a system present two main limitation; (1) the transactional database architecture, (2) the completeness of documentation. In order to solve the architectural problem, data warehouses were developed to propose architecture suitable for analysis. However, completeness of documentation stays unsolved. In this paper, we describe a method which allows determining of substitution rules in order to detect missing anesthesia events in an anesthesia record. Our method is based on the principle that missing event could be detected using a substitution one defined as the nearest documented event. As an example, we focused on the automatic detection of the start and the end of anesthesia procedure when these events were not documented by the clinicians. We applied our method on a set of records in order to evaluate; (1) the event detection accuracy, (2) the improvement of valid records. For the year 2010-2012, we obtained event detection with a precision of 0.00 (−2.22; 2.00) min for the start of anesthesia and 0.10 (0.00; 0.35) min for the end of anesthesia. On the other hand, we increased by 21.1% the data completeness (from 80.3 to 97.2% of the total database) for the start and the end of anesthesia events. This method seems to be efficient to replace missing "start and end of anesthesia” events. This method could also be used to replace other missing time events in this particular data warehouse as well as in other kind of data warehouses. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a AIMS  |2 nationallicence 
690 7 |a Data completeness  |2 nationallicence 
690 7 |a Substitution rule  |2 nationallicence 
690 7 |a Data warehouse  |2 nationallicence 
700 1 |a Lamer  |D Antoine  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
700 1 |a De Jonckheere  |D Julien  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
700 1 |a Marcilly  |D Romaric  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
700 1 |a Tavernier  |D Benoît  |u Pôle d'Anesthésie Réanimation, University Hospital, 59000, Lille, France  |4 aut 
700 1 |a Vallet  |D Benoît  |u Pôle d'Anesthésie Réanimation, University Hospital, 59000, Lille, France  |4 aut 
700 1 |a Jeanne  |D Mathieu  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
700 1 |a Logier  |D Régis  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
773 0 |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/6(2015-12-01), 741-747  |x 1387-1307  |q 29:6<741  |1 2015  |2 29  |o 10877 
856 4 0 |u https://doi.org/10.1007/s10877-015-9661-3  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10877-015-9661-3  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Lamer  |D Antoine  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a De Jonckheere  |D Julien  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Marcilly  |D Romaric  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Tavernier  |D Benoît  |u Pôle d'Anesthésie Réanimation, University Hospital, 59000, Lille, France  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Vallet  |D Benoît  |u Pôle d'Anesthésie Réanimation, University Hospital, 59000, Lille, France  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Jeanne  |D Mathieu  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Logier  |D Régis  |u INSERM CIC-IT, University Hospital, 59000, Lille, France  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/6(2015-12-01), 741-747  |x 1387-1307  |q 29:6<741  |1 2015  |2 29  |o 10877