Evaluation of near-infrared spectroscopy under apnea-dependent hypoxia in humans

Verfasser / Beitragende:
[Lars Eichhorn, Felix Erdfelder, Florian Kessler, Jonas Doerner, Marcus Thudium, Rainer Meyer, Richard Ellerkmann]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/6(2015-12-01), 749-757
Format:
Artikel (online)
ID: 605509875
LEADER caa a22 4500
001 605509875
003 CHVBK
005 20210128100643.0
007 cr unu---uuuuu
008 210128e20151201xx s 000 0 eng
024 7 0 |a 10.1007/s10877-015-9662-2  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10877-015-9662-2 
245 0 0 |a Evaluation of near-infrared spectroscopy under apnea-dependent hypoxia in humans  |h [Elektronische Daten]  |c [Lars Eichhorn, Felix Erdfelder, Florian Kessler, Jonas Doerner, Marcus Thudium, Rainer Meyer, Richard Ellerkmann] 
520 3 |a In this study we investigated the responsiveness of near-infrared spectroscopy (NIRS) recordings measuring regional cerebral tissue oxygenation (rSO2) during hypoxia in apneic divers. The goal was to mimic dynamic hypoxia as present during cardiopulmonary resuscitation, laryngospasm, airway obstruction, or the "cannot ventilate cannot intubate” situation. Ten experienced apneic divers performed maximal breath hold maneuvers under dry conditions. SpO2 was measured by Masimo™ pulse oximetry on the forefinger of the left hand. NIRS was measured by NONIN Medical's EQUANOX™ on the forehead or above the musculus quadriceps femoris. Following apnea median cerebral rSO2 and SpO2 values decreased significantly from 71 to 54 and from 100 to 65%, respectively. As soon as cerebral rSO2 and SpO2 values decreased monotonically the correlation between normalized cerebral rSO2 and SpO2 values was highly significant (Pearson correlation coefficient=0.893). Prior to correlation analyses, the values were normalized by dividing them by the individual means of stable pre-apneic measurements. Cerebral rSO2 measured re-saturation after termination of apnea significantly earlier (10s, SD=3.6s) compared to SpO2 monitoring (21s, SD=4.4s) [t(9)=7.703, p<0.001, r2=0.868]. Our data demonstrate that NIRS monitoring reliably measures dynamic changes in cerebral tissue oxygen saturation, and identifies successful re-saturation faster than SpO2. Measuring cerebral rSO2 may prove beneficial in case of respiratory emergencies and during pulseless situations where SpO2 monitoring is impossible. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a Hypoxia  |2 nationallicence 
690 7 |a NIRS  |2 nationallicence 
690 7 |a rSO2  |2 nationallicence 
690 7 |a SpO2  |2 nationallicence 
690 7 |a Apnea  |2 nationallicence 
700 1 |a Eichhorn  |D Lars  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
700 1 |a Erdfelder  |D Felix  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
700 1 |a Kessler  |D Florian  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
700 1 |a Doerner  |D Jonas  |u Department of Radiology, University Hospital Bonn, Bonn, Germany  |4 aut 
700 1 |a Thudium  |D Marcus  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
700 1 |a Meyer  |D Rainer  |u Institute of Physiology 2, University of Bonn, Bonn, Germany  |4 aut 
700 1 |a Ellerkmann  |D Richard  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
773 0 |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/6(2015-12-01), 749-757  |x 1387-1307  |q 29:6<749  |1 2015  |2 29  |o 10877 
856 4 0 |u https://doi.org/10.1007/s10877-015-9662-2  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10877-015-9662-2  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Eichhorn  |D Lars  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Erdfelder  |D Felix  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kessler  |D Florian  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Doerner  |D Jonas  |u Department of Radiology, University Hospital Bonn, Bonn, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Thudium  |D Marcus  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Meyer  |D Rainer  |u Institute of Physiology 2, University of Bonn, Bonn, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ellerkmann  |D Richard  |u Department of Anaesthesiology and Intensive Care Medicine, University Hospital Bonn, Bonn, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/6(2015-12-01), 749-757  |x 1387-1307  |q 29:6<749  |1 2015  |2 29  |o 10877