Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis

Verfasser / Beitragende:
[Lars Høiseth, Ingrid Hoff, Ove Hagen, Svein Landsverk, Knut Kirkebøen]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/4(2015-08-01), 435-441
Format:
Artikel (online)
ID: 605510121
LEADER caa a22 4500
001 605510121
003 CHVBK
005 20210128100644.0
007 cr unu---uuuuu
008 210128e20150801xx s 000 0 eng
024 7 0 |a 10.1007/s10877-015-9666-y  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10877-015-9666-y 
245 0 0 |a Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis  |h [Elektronische Daten]  |c [Lars Høiseth, Ingrid Hoff, Ove Hagen, Svein Landsverk, Knut Kirkebøen] 
520 3 |a The purpose of this analysis was to study agreement and trending of stroke volume measured by oesophageal Doppler and 3rd generation Vigileo during fluid loads in patients with severe aortic stenosis. Observational study in 32 patients (30 analyzed) scheduled for aortic valve replacement due to severe aortic stenosis. After induction of anesthesia and before start of surgery, hemodynamic registrations for 1min were obtained before and after a fluid load. Agreement between stroke volume measured by oesophageal Doppler (SVOD) and Vigileo (SVVig) was evaluated in Bland-Altman plot and trending in four-quadrant and polar plots. Bias±limits of agreement (LOA) between SVOD and SVVig was 24±37ml (percentage error 45%). Concordance of the two methods from before to after a fluid load was 100%. Angular bias±LOA was 12°±28°. Absolute values of SVOD and SVVig agreed poorly, but changes were highly concordant during fluid loads in aortic stenosis patients. The angular agreement indicated acceptable trending. The two measurement methods are not interchangeable in patients with aortic stenosis. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a Stroke volume  |2 nationallicence 
690 7 |a Aortic valve stenosis  |2 nationallicence 
690 7 |a Diagnostic techniques  |2 nationallicence 
690 7 |a Cardiovascular  |2 nationallicence 
700 1 |a Høiseth  |D Lars  |u Faculty of Medicine, University of Oslo, Oslo, Norway  |4 aut 
700 1 |a Hoff  |D Ingrid  |u Department of Anesthesiology, Oslo University Hospital, Kirkeveien 166, 0450, Oslo, Norway  |4 aut 
700 1 |a Hagen  |D Ove  |u Department of Anesthesiology, Oslo University Hospital, Kirkeveien 166, 0450, Oslo, Norway  |4 aut 
700 1 |a Landsverk  |D Svein  |u Department of Anesthesiology, Oslo University Hospital, Kirkeveien 166, 0450, Oslo, Norway  |4 aut 
700 1 |a Kirkebøen  |D Knut  |u Faculty of Medicine, University of Oslo, Oslo, Norway  |4 aut 
773 0 |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/4(2015-08-01), 435-441  |x 1387-1307  |q 29:4<435  |1 2015  |2 29  |o 10877 
856 4 0 |u https://doi.org/10.1007/s10877-015-9666-y  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10877-015-9666-y  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Høiseth  |D Lars  |u Faculty of Medicine, University of Oslo, Oslo, Norway  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Hoff  |D Ingrid  |u Department of Anesthesiology, Oslo University Hospital, Kirkeveien 166, 0450, Oslo, Norway  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Hagen  |D Ove  |u Department of Anesthesiology, Oslo University Hospital, Kirkeveien 166, 0450, Oslo, Norway  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Landsverk  |D Svein  |u Department of Anesthesiology, Oslo University Hospital, Kirkeveien 166, 0450, Oslo, Norway  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kirkebøen  |D Knut  |u Faculty of Medicine, University of Oslo, Oslo, Norway  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/4(2015-08-01), 435-441  |x 1387-1307  |q 29:4<435  |1 2015  |2 29  |o 10877