Utility of near infrared light to determine tissue oxygenation during hepato-biliary surgery
Gespeichert in:
Verfasser / Beitragende:
[N. Murphy, S. Fröhlich, T. Kong, J. Boylan, N. Conlon]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/5(2015-10-01), 613-619
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605510288 | ||
| 003 | CHVBK | ||
| 005 | 20210128100645.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20151001xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s10877-014-9642-y |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s10877-014-9642-y | ||
| 245 | 0 | 0 | |a Utility of near infrared light to determine tissue oxygenation during hepato-biliary surgery |h [Elektronische Daten] |c [N. Murphy, S. Fröhlich, T. Kong, J. Boylan, N. Conlon] |
| 520 | 3 | |a Near-infrared spectrophotometry assesses cerebral oxygen saturation (ScO2) based on the absorption spectra of oxygenated and deoxygenated hemoglobin, and the translucency of biological tissue, in the near-infrared band. There is increasing evidence that optimising cerebral oxygenation, guided by ScO2, is associated with improved outcomes in a variety of high risk surgical settings. However, in patients with liver disease, bilirubin can potentially render cerebral oximetry inaccurate. As a result, measurement of cerebral oxygen saturation is rarely undertaken in patients undergoing hepatobiliary surgery. We prospectively measured baseline and intraoperative cerebral oxygen saturation in patients undergoing major pancreatic surgery. Indices including bilirubin, sodium, platelets and maximum amplitude on thromboelastography were associated with low baseline ScO2. However, those patients with low ScO2 (≤51%) maintained a similar trend in cerebral oximetry values both at induction and intraoperatively to those with a normal ScO2. We conclude that the pattern of cerebral oximetry is similar in patients undergoing major pancreatic surgery regardless of their underlying liver dysfunction. Therefore, cerebral oximetry may have a role in monitoring neurological function in this high risk group of patients. | |
| 540 | |a Springer Science+Business Media New York, 2014 | ||
| 690 | 7 | |a Cerebral oximetry |2 nationallicence | |
| 690 | 7 | |a Bilirubin |2 nationallicence | |
| 690 | 7 | |a Liver |2 nationallicence | |
| 690 | 7 | |a Hepatobiliary |2 nationallicence | |
| 700 | 1 | |a Murphy |D N. |u Department of Anaesthesia and Intensive Care Medicine, St Vincent's University Hospital, Dublin 4, Ireland |4 aut | |
| 700 | 1 | |a Fröhlich |D S. |u Department of Anaesthesia and Intensive Care Medicine, St Vincent's University Hospital, Dublin 4, Ireland |4 aut | |
| 700 | 1 | |a Kong |D T. |u Department of Anaesthesia and Intensive Care Medicine, Galway University Hospital, Galway, Ireland |4 aut | |
| 700 | 1 | |a Boylan |D J. |u Department of Anaesthesia and Intensive Care Medicine, St Vincent's University Hospital, Dublin 4, Ireland |4 aut | |
| 700 | 1 | |a Conlon |D N. |u Department of Anaesthesia and Intensive Care Medicine, St Vincent's University Hospital, Dublin 4, Ireland |4 aut | |
| 773 | 0 | |t Journal of Clinical Monitoring and Computing |d Springer Netherlands |g 29/5(2015-10-01), 613-619 |x 1387-1307 |q 29:5<613 |1 2015 |2 29 |o 10877 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s10877-014-9642-y |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s10877-014-9642-y |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Murphy |D N. |u Department of Anaesthesia and Intensive Care Medicine, St Vincent's University Hospital, Dublin 4, Ireland |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Fröhlich |D S. |u Department of Anaesthesia and Intensive Care Medicine, St Vincent's University Hospital, Dublin 4, Ireland |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Kong |D T. |u Department of Anaesthesia and Intensive Care Medicine, Galway University Hospital, Galway, Ireland |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Boylan |D J. |u Department of Anaesthesia and Intensive Care Medicine, St Vincent's University Hospital, Dublin 4, Ireland |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Conlon |D N. |u Department of Anaesthesia and Intensive Care Medicine, St Vincent's University Hospital, Dublin 4, Ireland |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Journal of Clinical Monitoring and Computing |d Springer Netherlands |g 29/5(2015-10-01), 613-619 |x 1387-1307 |q 29:5<613 |1 2015 |2 29 |o 10877 | ||