Change in auditory evoked potential index and bispectral index during induction of anesthesia with anesthetic drugs
Gespeichert in:
Verfasser / Beitragende:
[Sachiko Matsushita, Shinya Oda, Kei Otaki, Masaki Nakane, Kaneyuki Kawamae]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/5(2015-10-01), 621-626
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605510342 | ||
| 003 | CHVBK | ||
| 005 | 20210128100645.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20151001xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s10877-014-9643-x |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s10877-014-9643-x | ||
| 245 | 0 | 0 | |a Change in auditory evoked potential index and bispectral index during induction of anesthesia with anesthetic drugs |h [Elektronische Daten] |c [Sachiko Matsushita, Shinya Oda, Kei Otaki, Masaki Nakane, Kaneyuki Kawamae] |
| 520 | 3 | |a The aim of this study was to evaluate the efficacy of the auditory evoked potential (AEP) index (aepEX) as an assessment tool for hypnosis during induction of various anesthetic drugs, and to compare its performance to that of the bispectral index (BIS). A total of 45 cases were divided into three groups based on the drugs used for anesthesia. Before anesthetic induction, BIS and AEP monitors were initiated. Anesthesia was induced through intravenous injection (IV) as follows: MP (n=15) group, midazolam (0.1mg/kg IV); TP (n=15) group, thiopental (4mg/kg IV); and KP (n=15) group, ketamine (2mg/kg IV). After loss of response (LOR), an infusion of 3μg/ml propofol via a target-controlled infusion was initiated in all groups. AepEX and BIS were measured in the waking state (baseline) and at LOR (1min after LOR), pre-intubation (1min after previous intubation) and post-intubation (1min after tracheal intubation finished). The value of aepEX significantly decreased in all groups with LOR and that of BIS also decreased except of KP group. No significant difference were observed in BIS values between baseline and LOR in the KS group. The aepEX might be more useful than BIS for hypnosis monitoring during anesthetic induction, particularly when drugs such as ketamine are used. | |
| 540 | |a The Author(s), 2014 | ||
| 690 | 7 | |a Auditory evoked potential |2 nationallicence | |
| 690 | 7 | |a Bispectral index |2 nationallicence | |
| 690 | 7 | |a Depth of anesthesia monitors |2 nationallicence | |
| 700 | 1 | |a Matsushita |D Sachiko |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | |
| 700 | 1 | |a Oda |D Shinya |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | |
| 700 | 1 | |a Otaki |D Kei |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | |
| 700 | 1 | |a Nakane |D Masaki |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | |
| 700 | 1 | |a Kawamae |D Kaneyuki |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | |
| 773 | 0 | |t Journal of Clinical Monitoring and Computing |d Springer Netherlands |g 29/5(2015-10-01), 621-626 |x 1387-1307 |q 29:5<621 |1 2015 |2 29 |o 10877 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s10877-014-9643-x |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s10877-014-9643-x |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Matsushita |D Sachiko |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Oda |D Shinya |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Otaki |D Kei |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Nakane |D Masaki |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Kawamae |D Kaneyuki |u Department of Anesthesiology, Faculty of Medicine, Yamagata University, Iida-nishi 2-2-2, Yamagata-shi, 990-2323, Yamagata, Japan |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Journal of Clinical Monitoring and Computing |d Springer Netherlands |g 29/5(2015-10-01), 621-626 |x 1387-1307 |q 29:5<621 |1 2015 |2 29 |o 10877 | ||