Evaluation of filtering methods for acquiring radial intra-artery blood pressure waveforms

Verfasser / Beitragende:
[Lawrence Hersh, Bruce Friedman, William Luczyk, Jean Sesing]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Clinical Monitoring and Computing, 29/5(2015-10-01), 659-669
Format:
Artikel (online)
ID: 605510377
LEADER caa a22 4500
001 605510377
003 CHVBK
005 20210128100645.0
007 cr unu---uuuuu
008 210128e20151001xx s 000 0 eng
024 7 0 |a 10.1007/s10877-014-9649-4  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10877-014-9649-4 
245 0 0 |a Evaluation of filtering methods for acquiring radial intra-artery blood pressure waveforms  |h [Elektronische Daten]  |c [Lawrence Hersh, Bruce Friedman, William Luczyk, Jean Sesing] 
520 3 |a The methods for evaluating noninvasive blood pressure (NIBP) monitors using an intra-arterial reference are detailed in the ANSI/AAMI/ISO 81060-2:2009 standard. In a recent study, GE Healthcare obtained invasive radial arterial blood pressure waveforms. The work presented here describes the development of filtering strategies for obtaining high fidelity intra-arterial pressure waveforms for NIBP accuracy testing using the 81060-2 standard. The natural frequency and damping factor of each subject-catheter-transducer system was computed from fast-flush transients. These parameters were used to construct filters for removing or reducing resonance artifacts. Additionally, new optimal damping factors were evaluated for designing compensation filters. Theoretical measurement systems using actual damping factors (<0.4) and natural frequencies were found capable of generating significant systolic resonance artifacts (≥8mmHg). Typical filters that may be standardly available in monitoring equipment were observed to be potentially inadequate in removing resonance artifact. Filters with particular optimal damping factors (0.6-0.7) were effective in removing resonance artifact. Clinicians need to understand that resonance artifacts potentially exist in intra-arterial waveforms and that the adjustments of monitoring systems may not be adequate. Optimal filters for obtaining intra-arterial waveforms should take into account the damping factor and natural frequency of the measuring system. In research and device evaluation studies it is necessary that optimal filtering be done to minimize the effects of under-damping. 
540 |a Springer Science+Business Media New York, 2014 
690 7 |a Intra-arterial blood pressure waveform filtering  |2 nationallicence 
690 7 |a Noninvasive blood pressure  |2 nationallicence 
690 7 |a Natural frequency  |2 nationallicence 
690 7 |a Damping factor  |2 nationallicence 
690 7 |a Filter design  |2 nationallicence 
700 1 |a Hersh  |D Lawrence  |u GE Healthcare, 8200 West Tower Avenue, 53223, Milwaukee, WI, USA  |4 aut 
700 1 |a Friedman  |D Bruce  |u GE Healthcare, 8200 West Tower Avenue, 53223, Milwaukee, WI, USA  |4 aut 
700 1 |a Luczyk  |D William  |u GE Healthcare, 8200 West Tower Avenue, 53223, Milwaukee, WI, USA  |4 aut 
700 1 |a Sesing  |D Jean  |u GE Healthcare, 8200 West Tower Avenue, 53223, Milwaukee, WI, USA  |4 aut 
773 0 |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/5(2015-10-01), 659-669  |x 1387-1307  |q 29:5<659  |1 2015  |2 29  |o 10877 
856 4 0 |u https://doi.org/10.1007/s10877-014-9649-4  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10877-014-9649-4  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Hersh  |D Lawrence  |u GE Healthcare, 8200 West Tower Avenue, 53223, Milwaukee, WI, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Friedman  |D Bruce  |u GE Healthcare, 8200 West Tower Avenue, 53223, Milwaukee, WI, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Luczyk  |D William  |u GE Healthcare, 8200 West Tower Avenue, 53223, Milwaukee, WI, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Sesing  |D Jean  |u GE Healthcare, 8200 West Tower Avenue, 53223, Milwaukee, WI, USA  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Journal of Clinical Monitoring and Computing  |d Springer Netherlands  |g 29/5(2015-10-01), 659-669  |x 1387-1307  |q 29:5<659  |1 2015  |2 29  |o 10877