<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605510458</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100646.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10877-014-9605-3</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10877-014-9605-3</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">In-line pressure within a HOTLINE® Fluid Warmer, under various flow conditions</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Midoriko Higashi, Ken Yamaura, Yukie Matsubara, Takuya Fukudome, Sumio Hoka]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Roller pump infusion devices are widely used for rapid infusion, and may be combined with separate warming devices. There may be instances however, where the pressures generated by the roller pump may not be compatible with the warming device. We assessed a commonly used roller pump in combination with a HOTLINE® Fluid Warmer, and found that it could generate pressures exceeding the HOTLINE® manufacturers specifications. This was of concern because the HOTLINE® manufacturer guideline states that not for use with pressure devices generating over 300mmHg. Pressure greater than 300mmHg may compromise the integrity of the HOTLINE® Fluid Warming Set. The aim of this study was to compare in-line pressure within a HOTLINE® Fluid Warmer at different infusion rates of a roller pump using various sizes of intravenous cannulae. The rapid infusion system comprised a 500mL-normal saline bag, roller pump type infusion device, HOTLINE® Fluid Warmer (blood and fluid warmer system), and six different sizes of intravenous cannulae. In-line pressure was measured proximal to the HOTLINE® (pre-warmer) and proximal to the cannula (post-warmer), at flow rate of 50-160mL/min. The in-line pressures increased significantly with increasing flow rate. The pre-warmer pressures exceeded 300mmHg when the flow rate was ≥120mL/min with 20-gauge, 48mm length cannula, 130 with 20-gauge, 25mm cannula, and 160mL/min with 18-gauge, 48mm cannula. However, they were &lt;300mmHg at any flow rates with 18-gauge, 30mm cannula and 16-gauge cannulae. The post-warmer pressures exceeded 300mmHg at theflow rate of 140mL/min with 20-gauge, 48mm cannula, and 160mL/min with 20-gauge, 25mm cannula, while they were &lt;300mmHg at any flow rates with 18 and 16-gauge cannulae. The in-line pressure within a HOTLINE® could exceed 300mmHg, depending on the flow rate and size and length of cannula. It is important to pay attention to the size and length of cannulae and flow rate to keep the maximum in-line pressure &lt;300mmHg when a roller pump type infusion device is used.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media New York, 2014</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">In-line pressure</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Rapid infusion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Roller pump</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Fluid warmer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Higashi</subfield>
   <subfield code="D">Midoriko</subfield>
   <subfield code="u">Operating Rooms, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, 812-8582, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Yamaura</subfield>
   <subfield code="D">Ken</subfield>
   <subfield code="u">Operating Rooms, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, 812-8582, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Matsubara</subfield>
   <subfield code="D">Yukie</subfield>
   <subfield code="u">Department of Anesthesiology and Critical Care Medicine, Kyushu University Hospital, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Fukudome</subfield>
   <subfield code="D">Takuya</subfield>
   <subfield code="u">Department of Anesthesiology and Critical Care Medicine, Kyushu University Hospital, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hoka</subfield>
   <subfield code="D">Sumio</subfield>
   <subfield code="u">Department of Anesthesiology and Critical Care Medicine, Kyushu University Hospital, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Clinical Monitoring and Computing</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">29/2(2015-04-01), 301-305</subfield>
   <subfield code="x">1387-1307</subfield>
   <subfield code="q">29:2&lt;301</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">29</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10877-014-9605-3</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10877-014-9605-3</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Higashi</subfield>
   <subfield code="D">Midoriko</subfield>
   <subfield code="u">Operating Rooms, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, 812-8582, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Yamaura</subfield>
   <subfield code="D">Ken</subfield>
   <subfield code="u">Operating Rooms, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, 812-8582, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Matsubara</subfield>
   <subfield code="D">Yukie</subfield>
   <subfield code="u">Department of Anesthesiology and Critical Care Medicine, Kyushu University Hospital, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Fukudome</subfield>
   <subfield code="D">Takuya</subfield>
   <subfield code="u">Department of Anesthesiology and Critical Care Medicine, Kyushu University Hospital, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hoka</subfield>
   <subfield code="D">Sumio</subfield>
   <subfield code="u">Department of Anesthesiology and Critical Care Medicine, Kyushu University Hospital, Fukuoka, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Clinical Monitoring and Computing</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">29/2(2015-04-01), 301-305</subfield>
   <subfield code="x">1387-1307</subfield>
   <subfield code="q">29:2&lt;301</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">29</subfield>
   <subfield code="o">10877</subfield>
  </datafield>
 </record>
</collection>
