The arrhythmogenic effect of ultrasonic exposure with acoustic radiation force (ARF) impulse on the rabbit heart with ultrasound contrast agent perfluorobutane

Verfasser / Beitragende:
[Yasunao Ishiguro, Hideki Sasanuma, Naotaka Nitta, Nobuyuki Taniguchi, Yukiyo Ogata, Yoshikazu Yasuda, Iwaki Akiyama]
Ort, Verlag, Jahr:
2015
Enthalten in:
Journal of Medical Ultrasonics, 42/1(2015-01-01), 47-50
Format:
Artikel (online)
ID: 605539227
LEADER caa a22 4500
001 605539227
003 CHVBK
005 20210128100905.0
007 cr unu---uuuuu
008 210128e20150101xx s 000 0 eng
024 7 0 |a 10.1007/s10396-014-0573-5  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10396-014-0573-5 
245 0 4 |a The arrhythmogenic effect of ultrasonic exposure with acoustic radiation force (ARF) impulse on the rabbit heart with ultrasound contrast agent perfluorobutane  |h [Elektronische Daten]  |c [Yasunao Ishiguro, Hideki Sasanuma, Naotaka Nitta, Nobuyuki Taniguchi, Yukiyo Ogata, Yoshikazu Yasuda, Iwaki Akiyama] 
520 3 |a Purpose: Acoustic radiation force (ARF) impulse can be used to estimate the elasticity of cardiac muscle. The purpose of this study was to evaluate the effect of ARF on the heart with concomitant administration of the ultrasound contrast agent (UCA) perfluorobutane for recently developed elasticity imaging such as shear wave imaging. Methods: Ultrasound with ARF was applied to the heart of Japanese white rabbit with or without UCA administration. During the exposure, electrocardiographs were recorded. Results: Following the exposure of ultrasound with a duration of 10ms and a mechanical index (MI) of 4.0 to the heart, extra waves (QRS complex) were observed only after UCA administration. Although life-threatening arrhythmia was not observed, a greater increase in the frequency of the extra waves was observed following a drip infusion compared with a single (bolus) UCA infusion. In addition, 16.3% of extra waves were followed by arterial pressure pulse. Conclusions: Cardiac ultrasound with higher MI and longer duration should be carefully considered, particularly with the concomitant use of UCA and higher MI. 
540 |a The Japan Society of Ultrasonics in Medicine, 2014 
690 7 |a Acoustic radiation force  |2 nationallicence 
690 7 |a Ultrasound contrast agent  |2 nationallicence 
690 7 |a Heart  |2 nationallicence 
690 7 |a Rabbit  |2 nationallicence 
690 7 |a Arrhythmia  |2 nationallicence 
690 7 |a Long duration  |2 nationallicence 
690 7 |a High MI  |2 nationallicence 
700 1 |a Ishiguro  |D Yasunao  |u Department of Surgery, Jichi Medical University, School of Medicine, 3311-1 Yakushiji, 329-0498, Shimotsuke, Tochigi, Japan  |4 aut 
700 1 |a Sasanuma  |D Hideki  |u Department of Surgery, Jichi Medical University, School of Medicine, 3311-1 Yakushiji, 329-0498, Shimotsuke, Tochigi, Japan  |4 aut 
700 1 |a Nitta  |D Naotaka  |u Human Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan  |4 aut 
700 1 |a Taniguchi  |D Nobuyuki  |u Department of Clinical Laboratory Medicine, Jichi Medical University, School of Medicine, Shimotsuke, Tochigi, Japan  |4 aut 
700 1 |a Ogata  |D Yukiyo  |u Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University, School of Medicine, Shimotsuke, Tochigi, Japan  |4 aut 
700 1 |a Yasuda  |D Yoshikazu  |u Department of Surgery, Jichi Medical University, School of Medicine, 3311-1 Yakushiji, 329-0498, Shimotsuke, Tochigi, Japan  |4 aut 
700 1 |a Akiyama  |D Iwaki  |u Faculty of Life and Medical Sciences, Doshisha University, Kyotanabe, Kyoto, Japan  |4 aut 
773 0 |t Journal of Medical Ultrasonics  |d Springer Japan  |g 42/1(2015-01-01), 47-50  |x 1346-4523  |q 42:1<47  |1 2015  |2 42  |o 10396 
856 4 0 |u https://doi.org/10.1007/s10396-014-0573-5  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10396-014-0573-5  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ishiguro  |D Yasunao  |u Department of Surgery, Jichi Medical University, School of Medicine, 3311-1 Yakushiji, 329-0498, Shimotsuke, Tochigi, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Sasanuma  |D Hideki  |u Department of Surgery, Jichi Medical University, School of Medicine, 3311-1 Yakushiji, 329-0498, Shimotsuke, Tochigi, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Nitta  |D Naotaka  |u Human Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Taniguchi  |D Nobuyuki  |u Department of Clinical Laboratory Medicine, Jichi Medical University, School of Medicine, Shimotsuke, Tochigi, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Ogata  |D Yukiyo  |u Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University, School of Medicine, Shimotsuke, Tochigi, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Yasuda  |D Yoshikazu  |u Department of Surgery, Jichi Medical University, School of Medicine, 3311-1 Yakushiji, 329-0498, Shimotsuke, Tochigi, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Akiyama  |D Iwaki  |u Faculty of Life and Medical Sciences, Doshisha University, Kyotanabe, Kyoto, Japan  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Journal of Medical Ultrasonics  |d Springer Japan  |g 42/1(2015-01-01), 47-50  |x 1346-4523  |q 42:1<47  |1 2015  |2 42  |o 10396