<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605539693</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100908.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20151001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10396-015-0640-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10396-015-0640-6</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Weighted Capon beamformer combined with coded excitation in ultrasound imaging</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Seyed Izadi, Ali Mahloojifar, Babak Asl]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Background: Capon-based beamformers are well-known methods to improve the SNR and quality of medical ultrasound images. Furthermore, they can improve the resolution of the images unexpectedly more than conventional DAS beamformers. Another method used in radar, sonar, and ultrasound imaging to increase the SNR is coded excitation with linear frequency-modulated signal (chirp). Method: In this paper, we illustrate that the combination of coded excitation with a Capon beamformer provides better resolution and higher SNR. However, this combination suffers from high sidelobe levels. We propose a weighted Capon beamformer (WCB) with chirp excitation to suppress the sidelobes and obtain a higher contrast with approximately the same resolution as the standard Capon beamformer (SCB). The weights of the WCB are obtained using element-wise multiplication of the weights of the SCB and a desired window (Hanning) with the same dimension. Results: The results show a 20dB reduction in the sidelobe levels in simulated point targets and a 6dB increase in background contrast in simulated cyst phantoms.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">The Japan Society of Ultrasonics in Medicine, 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Capon</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Minimum variance</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Adaptive beamformer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Coded excitation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Chirp</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Izadi</subfield>
   <subfield code="D">Seyed</subfield>
   <subfield code="u">Department of Biomedical Engineering, Tarbiat Modares University, Ale-Ahmad Avenue, P.o. Box 14115-194, Tehran, Islamic Republic of Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mahloojifar</subfield>
   <subfield code="D">Ali</subfield>
   <subfield code="u">Department of Biomedical Engineering, Tarbiat Modares University, Ale-Ahmad Avenue, P.o. Box 14115-194, Tehran, Islamic Republic of Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Asl</subfield>
   <subfield code="D">Babak</subfield>
   <subfield code="u">Department of Biomedical Engineering, Tarbiat Modares University, Ale-Ahmad Avenue, P.o. Box 14115-194, Tehran, Islamic Republic of Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Medical Ultrasonics</subfield>
   <subfield code="d">Springer Japan</subfield>
   <subfield code="g">42/4(2015-10-01), 477-488</subfield>
   <subfield code="x">1346-4523</subfield>
   <subfield code="q">42:4&lt;477</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">42</subfield>
   <subfield code="o">10396</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10396-015-0640-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10396-015-0640-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Izadi</subfield>
   <subfield code="D">Seyed</subfield>
   <subfield code="u">Department of Biomedical Engineering, Tarbiat Modares University, Ale-Ahmad Avenue, P.o. Box 14115-194, Tehran, Islamic Republic of Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mahloojifar</subfield>
   <subfield code="D">Ali</subfield>
   <subfield code="u">Department of Biomedical Engineering, Tarbiat Modares University, Ale-Ahmad Avenue, P.o. Box 14115-194, Tehran, Islamic Republic of Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Asl</subfield>
   <subfield code="D">Babak</subfield>
   <subfield code="u">Department of Biomedical Engineering, Tarbiat Modares University, Ale-Ahmad Avenue, P.o. Box 14115-194, Tehran, Islamic Republic of Iran</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Medical Ultrasonics</subfield>
   <subfield code="d">Springer Japan</subfield>
   <subfield code="g">42/4(2015-10-01), 477-488</subfield>
   <subfield code="x">1346-4523</subfield>
   <subfield code="q">42:4&lt;477</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">42</subfield>
   <subfield code="o">10396</subfield>
  </datafield>
 </record>
</collection>
