The Use of 1H NMR and PCA for Quality Assessment of Gasoline of Different Octane Number
Gespeichert in:
Verfasser / Beitragende:
[Safwan Obeidat]
Ort, Verlag, Jahr:
2015
Enthalten in:
Applied Magnetic Resonance, 46/8(2015-08-01), 875-883
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605545987 | ||
| 003 | CHVBK | ||
| 005 | 20210128100938.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20150801xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s00723-015-0692-1 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s00723-015-0692-1 | ||
| 100 | 1 | |a Obeidat |D Safwan |u Department of Chemistry, Yarmouk University, Irbid, Jordan |4 aut | |
| 245 | 1 | 4 | |a The Use of 1H NMR and PCA for Quality Assessment of Gasoline of Different Octane Number |h [Elektronische Daten] |c [Safwan Obeidat] |
| 520 | 3 | |a In this study, successful discrimination between two types of gasoline of different octane number (90 and 95) was achieved. 24 samples of each type of gasoline were collected and analyzed with 1H NMR and processed with PCA and kNN. Uncovering adulterated gasoline 95 samples with gasoline 90 of different composition ratios of gasoline 90 (2.5, 5, 10, 20) % v/v have also been achieved by preparing 12 adulterated sample and applying the resulted 1H nuclear magnetic resonance (NMR) data to the original PCA model. The determination of adulteration composition was achieved using the 1H NMR spectra quantitatively through the least square linear regression analysis. | |
| 540 | |a Springer-Verlag Wien, 2015 | ||
| 773 | 0 | |t Applied Magnetic Resonance |d Springer Vienna |g 46/8(2015-08-01), 875-883 |x 0937-9347 |q 46:8<875 |1 2015 |2 46 |o 723 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00723-015-0692-1 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s00723-015-0692-1 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 100 |E 1- |a Obeidat |D Safwan |u Department of Chemistry, Yarmouk University, Irbid, Jordan |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Applied Magnetic Resonance |d Springer Vienna |g 46/8(2015-08-01), 875-883 |x 0937-9347 |q 46:8<875 |1 2015 |2 46 |o 723 | ||