<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605546010</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100938.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150801xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00723-015-0695-y</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00723-015-0695-y</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Influence of Iodinated Contrast Media and Isotope 99mTc on Changes of Signal to Noise Ratio of Magnetic Resonance Imaging</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Jin-Hyeok Lee, Hae-Kag Lee, Jae-Hwan Cho]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The purpose of the study is to find out the changes of the signal-to-noise ratio (SNR) of magnetic resonance imaging (MRI) when performing MRI, computed tomography (CT), and isotope examination using 99mTc. For the study, divide the phantoms into two groups: (1) saline, saline+different kinds of contrast agent without 99mTc administration; (2) 99mTc administration: saline, saline+different kinds of the contrast agent with 99mTc administration. The CT contrast agent was used for Iopamidol® and Dotarem. And MRI contrast agent was used for Primovist® and Gadovist®. To obtain image, we used 3.0T MR System, and obtainedT1and T2 images. Using obtained image, we compared an average value of SNR of T1 and T2 before and after distributing 99mTc. As a result, SNR in T1 images had a significant difference before and after putting 99mTc to every contrast media except normal saline. Also SNR in T2 mages had a significant difference before and after putting 99mTc in every contrast media except Gadovist®.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Wien, 2015</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lee</subfield>
   <subfield code="D">Jin-Hyeok</subfield>
   <subfield code="u">Department of Radiology, Korea Veterans Hospital, Seoul, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lee</subfield>
   <subfield code="D">Hae-Kag</subfield>
   <subfield code="u">Department of Computer Science and Engineering, Soonchunhyang University, Asan, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Cho</subfield>
   <subfield code="D">Jae-Hwan</subfield>
   <subfield code="u">Department of International Radiological Science, Hallym University of Graduate Studies, 427, Yeoksam-ro, Gangnam-gu, 135-841, Seoul, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Applied Magnetic Resonance</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">46/8(2015-08-01), 931-940</subfield>
   <subfield code="x">0937-9347</subfield>
   <subfield code="q">46:8&lt;931</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">46</subfield>
   <subfield code="o">723</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00723-015-0695-y</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00723-015-0695-y</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lee</subfield>
   <subfield code="D">Jin-Hyeok</subfield>
   <subfield code="u">Department of Radiology, Korea Veterans Hospital, Seoul, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lee</subfield>
   <subfield code="D">Hae-Kag</subfield>
   <subfield code="u">Department of Computer Science and Engineering, Soonchunhyang University, Asan, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Cho</subfield>
   <subfield code="D">Jae-Hwan</subfield>
   <subfield code="u">Department of International Radiological Science, Hallym University of Graduate Studies, 427, Yeoksam-ro, Gangnam-gu, 135-841, Seoul, Republic of Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Applied Magnetic Resonance</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">46/8(2015-08-01), 931-940</subfield>
   <subfield code="x">0937-9347</subfield>
   <subfield code="q">46:8&lt;931</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">46</subfield>
   <subfield code="o">723</subfield>
  </datafield>
 </record>
</collection>
