<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">606221174</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128101127.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00380-014-0525-4</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00380-014-0525-4</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="2">
   <subfield code="a">A novel technique to predict pulmonary capillary wedge pressure utilizing central venous pressure and tissue Doppler tricuspid/mitral annular velocities</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Kazunori Uemura, Masashi Inagaki, Can Zheng, Meihua Li, Toru Kawada, Masaru Sugimachi]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Assessing left ventricular (LV) filling pressure (pulmonary capillary wedge pressure, PCWP) is an important aspect in the care of patients with heart failure (HF). Physicians rely on right ventricular (RV) filling pressures such as central venous pressure (CVP) to predict PCWP, assuming concordance between CVP and PCWP. However, the use of this method is limited because discordance between CVP and PCWP is observed. We hypothesized that PCWP can be reliably predicted by CVP corrected by the relationship between RV and LV function, provided by the ratio of tissue Doppler peak systolic velocity of tricuspid annulus (S T) to that of mitral annulus (S M) (corrected CVP:CVP·S T/S M). In 16 anesthetized closed-chest dogs, S T and S M were measured by transthoracic tissue Doppler echocardiography. PCWP was varied over a wide range (1.8-40.0mmHg) under normal condition and various types of acute and chronic HF. A significantly stronger linear correlation was observed between CVP·S T/S M and PCWP (R 2=0.78) than between CVP and PCWP (R 2=0.22) (P&lt;0.01). Receiver-operating characteristic (ROC) analysis indicated that CVP·S T/S M &gt;10.5mmHg predicted PCWP &gt;18mmHg with 85% sensitivity and 88% specificity. Area under ROC curve for CVP·S T/S M to predict PCWP &gt;18mmHg was 0.93, which was significantly larger than that for CVP (0.66) (P&lt;0.01). Peripheral venous pressure (PVP) corrected by S T/S M (PVP·S T/S M) also predicted PCWP reasonably well, suggesting that PVP·S T/S M may be a minimally invasive alternative to CVP·S T/S M. In conclusion, our technique is potentially useful for the reliable prediction of PCWP in HF patients.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Japan, 2014</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Heart failure</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Hemodynamics</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Echocardiography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Uemura</subfield>
   <subfield code="D">Kazunori</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Inagaki</subfield>
   <subfield code="D">Masashi</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Zheng</subfield>
   <subfield code="D">Can</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Li</subfield>
   <subfield code="D">Meihua</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kawada</subfield>
   <subfield code="D">Toru</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Sugimachi</subfield>
   <subfield code="D">Masaru</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Heart and Vessels</subfield>
   <subfield code="d">Springer Japan</subfield>
   <subfield code="g">30/4(2015-07-01), 516-526</subfield>
   <subfield code="x">0910-8327</subfield>
   <subfield code="q">30:4&lt;516</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">30</subfield>
   <subfield code="o">380</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00380-014-0525-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00380-014-0525-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Uemura</subfield>
   <subfield code="D">Kazunori</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Inagaki</subfield>
   <subfield code="D">Masashi</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Zheng</subfield>
   <subfield code="D">Can</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Li</subfield>
   <subfield code="D">Meihua</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kawada</subfield>
   <subfield code="D">Toru</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Sugimachi</subfield>
   <subfield code="D">Masaru</subfield>
   <subfield code="u">Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, 5-7-1 Fujishirodai, 565-8565, Suita, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Heart and Vessels</subfield>
   <subfield code="d">Springer Japan</subfield>
   <subfield code="g">30/4(2015-07-01), 516-526</subfield>
   <subfield code="x">0910-8327</subfield>
   <subfield code="q">30:4&lt;516</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">30</subfield>
   <subfield code="o">380</subfield>
  </datafield>
 </record>
</collection>
