<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">606244050</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128101328.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20151201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s12596-015-0290-5</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s12596-015-0290-5</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Calibration of grating based optical spectrum analyzers</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Osama Terra, Hatem Hussein]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">In this paper, three methods are used to calibrate a grating-based Optical Spectrum Analyzer (OSA). The first method is used to calibrate OSA over the full spectral range by using a set of well characterized laser sources. These lasers, whose wavelengths cover OSA range, are well characterized using a highly accurate wavemeter. The Accuracy and stability for some lasers are found sufficient to calibrate OSA without the need to have an online measurement with a wavemeter. The second method uses the advantage of phase matching in non-linear crystals to generate frequency doubled light with exactly half the wavelength to measure OSA wavelength scale accuracy, resolution and linearity. In the third method, a Hydrogen Cyanide (H13C14N) gas cell - (HCN) is used as wavelength reference to calibrate OSA in the wavelength range 1533-1557nm.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">The Optical Society of India, 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Optical spectrum analyzer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Hydrogen cyanide wavelength reference</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Terra</subfield>
   <subfield code="D">Osama</subfield>
   <subfield code="u">National Institute for Standard (NIS), Tersa St. Haram, P.O. Box: 136, 12211, Giza, Egypt</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hussein</subfield>
   <subfield code="D">Hatem</subfield>
   <subfield code="u">National Institute for Standard (NIS), Tersa St. Haram, P.O. Box: 136, 12211, Giza, Egypt</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Optics</subfield>
   <subfield code="d">Springer India</subfield>
   <subfield code="g">44/4(2015-12-01), 366-372</subfield>
   <subfield code="x">0972-8821</subfield>
   <subfield code="q">44:4&lt;366</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">44</subfield>
   <subfield code="o">12596</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s12596-015-0290-5</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s12596-015-0290-5</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Terra</subfield>
   <subfield code="D">Osama</subfield>
   <subfield code="u">National Institute for Standard (NIS), Tersa St. Haram, P.O. Box: 136, 12211, Giza, Egypt</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hussein</subfield>
   <subfield code="D">Hatem</subfield>
   <subfield code="u">National Institute for Standard (NIS), Tersa St. Haram, P.O. Box: 136, 12211, Giza, Egypt</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Optics</subfield>
   <subfield code="d">Springer India</subfield>
   <subfield code="g">44/4(2015-12-01), 366-372</subfield>
   <subfield code="x">0972-8821</subfield>
   <subfield code="q">44:4&lt;366</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">44</subfield>
   <subfield code="o">12596</subfield>
  </datafield>
 </record>
</collection>
