<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">606248927</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128101353.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20151201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s12262-014-1131-5</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s12262-014-1131-5</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Nath</subfield>
   <subfield code="D">Sisir</subfield>
   <subfield code="u">Department of Surgery, International Hospital, Lotus Tower, 781005, Guwahati, Assam, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Stapled Haemorrhoidectomy—Experience With Modified Anoscope</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Sisir Nath]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Stapled haemorrhoidectomy (SH) is gradually becoming popular. Though it is a &quot;patient friendly” procedure, it has not become the &quot;gold standard”. About 15% complication rate is reported. A perfect purse-string can avoid many of the complications. The author has made a semicircular hole in the anoscope, which has helped in taking the purse-string at proper depth and at proper distance from the dentate line. A total of 72 cases of SH are performed without any complication. Histopathological examination of donoughts in the first 20 cases shows excision up to the submucosa in 16 cases. Our modified anoscope helps in proper visualisation and proper pick up of the rectal wall for perfect purse-string suture and thus complications are avoided.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Association of Surgeons of India, 2014</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Stapled haemorrhoidectomy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Modified anoscope</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Purse-string suture</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Complications</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Indian Journal of Surgery</subfield>
   <subfield code="d">Springer India</subfield>
   <subfield code="g">77(2015-12-01), 1438-1440</subfield>
   <subfield code="x">0972-2068</subfield>
   <subfield code="q">77&lt;1438</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">77</subfield>
   <subfield code="o">12262</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s12262-014-1131-5</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s12262-014-1131-5</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Nath</subfield>
   <subfield code="D">Sisir</subfield>
   <subfield code="u">Department of Surgery, International Hospital, Lotus Tower, 781005, Guwahati, Assam, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Indian Journal of Surgery</subfield>
   <subfield code="d">Springer India</subfield>
   <subfield code="g">77(2015-12-01), 1438-1440</subfield>
   <subfield code="x">0972-2068</subfield>
   <subfield code="q">77&lt;1438</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">77</subfield>
   <subfield code="o">12262</subfield>
  </datafield>
 </record>
</collection>
